This project will be focused on designing a microfluidic device to visualize haemodynamics within a carotid-artery mimetic device. The system will be designed to evaluate associations especially between fibrinogen, erythrocytes, and platelets when subjected to shear and coagulation-inducing factors. The design will include biologically and mechanically variable properties as may occur in transient

Project Information FAQ

Project Information

3 Q
The project “Carotid-artery-on-a-chip device to model thromboembolisms induced by vascular lesions and perform drug screenings” is an infrastructure initiative in the Automotive sector, located in France. Taiyo aggregates data on it from EU Funding & Tenders Portal.

Want to explore the full details? View the full report

Participants

Sponsoring Agency

Obfuscated Data

Company

Obfuscated Data

Status

Original status

ended

Taiyo status

Obfuscated Data

Taiyo last update

00-00-0000

Available timestamps

00-00-0000

Available timestamp type

Obfuscated Data

Contact

Contact name

Obfuscated Data

Phone

0000000000

Email

ObfuscatedData@email.com

Address

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Description

Description

This project will be focused on designing a microfluidic device to visualize haemodynamics within a carotid-artery mimetic device. The system will be designed to evaluate associations especially between fibrinogen, erythrocytes, and platelets when subjected to shear and coagulation-inducing factors. The design will include biologically and mechanically variable properties as may occur in transient ischaemic attacks (TIA). The intended system is to have similar composition and dimensions as the extra-cranial (common to internal) carotid arteries. Physiologically relevant dimensions will be implemented where the common artery will have a lumen diameter of 6.1 mm with variable thickness (0.6 to 0.9 mm), whereas the internal artery will be 4.7 mm in diameter with thickness of 0.7mm. The system will be equipped with pressure and stretch-inducing mechanics which can be modulated to trigger rheological and biological responses. Specifically, stretching will cause exposure of tissue factor and lipids, capable of triggering inflammatory coagulation. The proximal formation of biological or physical occlusions will be assessed using this device. Also, the design will enable visualization of intra-vascular activity as may be illustrated in live high-resolution confocal microscopy. Flow properties of liquids with varied rheological properties similar to blood will be tested. Clinicians and researchers studying the pathology of strokes and TIAs or conducting studies on intravascular thrombosis will be able to engage this device in experiments while pharmaceutical developers will be able to engage the device in testing actions of therapeutic agents. Stroke remains the second leading cause of death globally and through the development of this device, both developers and potential users of the device will be able to explore effective and applicable solutions. Elvesys will avail the researcher an enriching environment to master IP, marketing concepts, patenting and public engagement.

Original sub-sector

Obfuscated

Original Currency

USD

Original budget

000000000000000

Procurement method

Obfuscated Data

Budget

000000000000000

Location

Region

Obfuscated

Country

Obfuscated

State

Obfuscated Data

County

Obfuscated

Location

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Source

Source reliability

High

Data quality score

100%

Source

Obfuscated Data

URL

obfuscated_data,obfuscateddata.com

More Details

Project Type

Obfuscated Data

Article Published Date

Obfuscated Data