Accurate electron beam current measurement at the specimen plane is fundamental to quantitative TEM, yet no reliable standard exists across major instrument platforms. Current approaches introduce systematic errors of 18 to 52% or are incompatible with the MEMS-based in situ holders needed for picoampere-level electrical measurements in operando devices. This gap prevents quantitative electron bea

Status
Prospective
Location
Germany
Updated
19 Nov 2026
Source
EU Funding & Tenders Portal

ConstructChat

Ask ConstructChat about Chip-based Accurate eLectron Intensity Beam Readout for Advanced TEM Experiments

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Project Information FAQ

Project Information

3 Q
The project “Chip-based Accurate eLectron Intensity Beam Readout for Advanced TEM Experiments” is an infrastructure initiative, located in Germany. Taiyo aggregates data on it from EU Funding & Tenders Portal.

Participants

Not available for this record.

Status

Original status

forthcoming

Taiyo status

Prospective

Taiyo last update

2026-11-19

Contact

Not available for this record.

Description

Description

Accurate electron beam current measurement at the specimen plane is fundamental to quantitative TEM, yet no reliable standard exists across major instrument platforms. Current approaches introduce systematic errors of 18 to 52% or are incompatible with the MEMS-based in situ holders needed for picoampere-level electrical measurements in operando devices. This gap prevents quantitative electron beam-induced current (EBIC) and secondary electron EBIC (SEEBIC) imaging, techniques increasingly critical for nanoscale materials and device characterisation. CALIBRATE addresses this by developing a calibration approach that makes accurate beam current measurement available directly at the sample position in MEMS-based in situ experiments, across instrument and holder platforms. The target is a measurement error below 5%. This would enable the first quantitative in situ EBIC/SEEBIC experiments and provide a traceable dose-control standard for the broader in situ TEM community.

Location

Country

Germany

Source

Source

EU Funding & Tenders Portal

URL

More Details

Record type

Project

Article published date

2026-10-01

More on this project

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this project
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this project