CHIRALSENSE : Sensing Chirality using cavity-enhanced polarimetry: advances in sensitivity and time-resolution
Sector: Commercial • Location: Greece
Source: EU Funding & Tenders Portal
Chiral sensing is crucial to many fields, constituting a multibillion Euro industry. The polarimetric techniques of optical rotation (OR) and circular dichroism (CD) are the most widely-used techniques for the analysis of chiral samples, ranging from the measurement of protein structure, to quality control in the pharmaceutical, chemical, cosmetic, and food industries. In general, the OR and CD si
Project Information FAQ
Project Information
Want to explore the full details? View the full report
Participants
Sponsoring Agency | Obfuscated Data |
Company | Obfuscated Data |
Status
Original status | ended |
Taiyo status | Obfuscated Data |
Taiyo last update | 00-00-0000 |
Available timestamps | 00-00-0000 |
Available timestamp type | Obfuscated Data |
Contact
Contact name | Obfuscated Data |
Phone | 0000000000 |
ObfuscatedData@email.com | |
Address | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Description
Description | Chiral sensing is crucial to many fields, constituting a multibillion Euro industry. The polarimetric techniques of optical rotation (OR) and circular dichroism (CD) are the most widely-used techniques for the analysis of chiral samples, ranging from the measurement of protein structure, to quality control in the pharmaceutical, chemical, cosmetic, and food industries. In general, the OR and CD signals are very small, which place severe constraints on detection sensitivity and time-resolution. Through the ERC grant TRICEPS, we have developed a groundbreaking cavity-based polarimeter [Sofikitis et al. Nature 514, 76 (2014)] with 3 main advantages: (a) The OR and CD signals are enhanced by the number of cavity passes (typically 1000); (b) birefringent backgrounds are suppressed; (c) signal reversals give absolute polarimetry measurements, not requiring the sample to be removed to measure a null sample. These advantages represent orders-of-magnitude improvements in sensitivity, acquisition time, and sample size, with respect to commercially available polarimeters, and will reduce measurement time, sample sizes, and costs in the chiral sensing industry. We propose, through CHIRALSENSE, to: (1) file a non-provisional US patent application, to follow our filing of a US provisional patent application for our polarimeter, which will provide IPR protection for the first stages of the product development; (2) demonstrate our existing CHIRALSENSE polarimeter to leading polarimetry companies, by performing measurements on commercial-standard samples; and (3) adapt our polarimeter to measure complex samples separated using HPLC (high-performance liquid chromatography) for analytical chemistry applications, to be demonstrated to leading HPLC companies. |
Original sub-sector | Obfuscated |
Original Currency | USD |
Original budget | 000000000000000 |
Procurement method | Obfuscated Data |
Budget | 000000000000000 |
Location
Region | Obfuscated |
Country | Obfuscated |
State | Obfuscated Data |
County | Obfuscated |
Location | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Source
Source reliability | High |
Data quality score | 100% |
Source | Obfuscated Data |
URL | obfuscated_data,obfuscateddata.com |
More Details
Project Type | Obfuscated Data |
Article Published Date | Obfuscated Data |
