logo

CHIRALSENSE : Sensing Chirality using cavity-enhanced polarimetry: advances in sensitivity and time-resolution

Sector: Commercial • Location: Greece

Source: EU Funding & Tenders Portal

Project
Ended

Chiral sensing is crucial to many fields, constituting a multibillion Euro industry. The polarimetric techniques of optical rotation (OR) and circular dichroism (CD) are the most widely-used techniques for the analysis of chiral samples, ranging from the measurement of protein structure, to quality control in the pharmaceutical, chemical, cosmetic, and food industries. In general, the OR and CD si

Project Information FAQ

Project Information

3 Q
The project “CHIRALSENSE : Sensing Chirality using cavity-enhanced polarimetry: advances in sensitivity and time-resolution” is an infrastructure initiative in the Commercial sector, located in Greece. Taiyo aggregates data on it from EU Funding & Tenders Portal.

Want to explore the full details? View the full report

Participants

Sponsoring Agency

Obfuscated Data

Company

Obfuscated Data

Status

Original status

ended

Taiyo status

Obfuscated Data

Taiyo last update

00-00-0000

Available timestamps

00-00-0000

Available timestamp type

Obfuscated Data

Contact

Contact name

Obfuscated Data

Phone

0000000000

Email

ObfuscatedData@email.com

Address

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Description

Description

Chiral sensing is crucial to many fields, constituting a multibillion Euro industry. The polarimetric techniques of optical rotation (OR) and circular dichroism (CD) are the most widely-used techniques for the analysis of chiral samples, ranging from the measurement of protein structure, to quality control in the pharmaceutical, chemical, cosmetic, and food industries. In general, the OR and CD signals are very small, which place severe constraints on detection sensitivity and time-resolution. Through the ERC grant TRICEPS, we have developed a groundbreaking cavity-based polarimeter [Sofikitis et al. Nature 514, 76 (2014)] with 3 main advantages: (a) The OR and CD signals are enhanced by the number of cavity passes (typically 1000); (b) birefringent backgrounds are suppressed; (c) signal reversals give absolute polarimetry measurements, not requiring the sample to be removed to measure a null sample. These advantages represent orders-of-magnitude improvements in sensitivity, acquisition time, and sample size, with respect to commercially available polarimeters, and will reduce measurement time, sample sizes, and costs in the chiral sensing industry. We propose, through CHIRALSENSE, to: (1) file a non-provisional US patent application, to follow our filing of a US provisional patent application for our polarimeter, which will provide IPR protection for the first stages of the product development; (2) demonstrate our existing CHIRALSENSE polarimeter to leading polarimetry companies, by performing measurements on commercial-standard samples; and (3) adapt our polarimeter to measure complex samples separated using HPLC (high-performance liquid chromatography) for analytical chemistry applications, to be demonstrated to leading HPLC companies.

Original sub-sector

Obfuscated

Original Currency

USD

Original budget

000000000000000

Procurement method

Obfuscated Data

Budget

000000000000000

Location

Region

Obfuscated

Country

Obfuscated

State

Obfuscated Data

County

Obfuscated

Location

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Source

Source reliability

High

Data quality score

100%

Source

Obfuscated Data

URL

obfuscated_data,obfuscateddata.com

More Details

Project Type

Obfuscated Data

Article Published Date

Obfuscated Data