During a study in 2016, it was found that a drinking water line was crossing through the sanitary sewer system. The water line must be separated from the sewer line, which requires an engineered redesign to ensure applicable standards are met and hydraulic integrity of the distribution system is not adversely affected. (Phase 1 of 2, Phase 2 will be the physical separation of the watermain from th
- Status
- Closed
- Sector
- Water Supply and Storage, Government, Road, Waste Processing and Treatment, Power Transmission, Power Generation (CCGT)
- Location
- Ontario, Canada
- Updated
- 22 Jul 2026
- Source
- Infrastructure Canada
ConstructChat
Ask ConstructChat about Design needed for the separation of the drinking water and the sewer line as the water line is crossing the sewer line. (phase 1 of 2)
Pick a question to edit it, or write your own.
First answer free · no account
Project Information FAQ
Project Information
Participants
Sponsoring Agency |
Status
Original status | completed |
Taiyo status | Closed |
Taiyo last update | 2026-07-22 |
Contact
| Not available for this record. |
Description
Description | During a study in 2016, it was found that a drinking water line was crossing through the sanitary sewer system. The water line must be separated from the sewer line, which requires an engineered redesign to ensure applicable standards are met and hydraulic integrity of the distribution system is not adversely affected. (Phase 1 of 2, Phase 2 will be the physical separation of the watermain from the sewer main and is further described in next project.) Objective: To create a design to separate the water and sewage piping which presently intersect as identified in the Closed-circuit television inspections. This design must consider the required separation required between sanitary sewers and municipal water system pipe. Scope: Procure Engineering Consultant. Consultant to design an alternate watermain route that meets requirements and can be used to perform or tender construction in Phase 2. Output: Engineered drawing that clearly describe details required by constructors, including but not limited to material, required depths of each utility, backfill required, surfacing required, and any details of use to the contractor. |
Original sector | Drinking Water and Wastewater |
Location
Country | Canada |
State | Ontario |
Source
Source | Infrastructure Canada |
URL |
More Details
Record type | Project |
Sector | Water Supply and Storage, Government, Road, Waste Processing and Treatment, Power Transmission, Power Generation (CCGT) |
Article published date | 2025-10-05 |