Development of a Master Socket for optimised design of prosthetic socket for lower limb amputees
Source: EU Funding & Tenders Portal
The function of a lower limb prosthetic is highly dependent upon the characteristics and anatomical profile of the residual limb. This is unique to each individual and changes depending on the activities being engaged in by the amputee. A poorly fitting prosthetic socket can cause significant trauma so it is important to consider how to optimise the fit to maximise the amputee's comfort whilst we
Project Information FAQ
Project Information
Want to explore the full details? View the full report
Participants
Sponsoring Agency | Obfuscated Data |
Company | Obfuscated Data |
Status
Original status | ended |
Taiyo status | Obfuscated Data |
Taiyo last update | 00-00-0000 |
Available timestamps | 00-00-0000 |
Available timestamp type | Obfuscated Data |
Contact
Contact name | Obfuscated Data |
Phone | 0000000000 |
ObfuscatedData@email.com | |
Address | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Description
Description | The function of a lower limb prosthetic is highly dependent upon the characteristics and anatomical profile of the residual limb. This is unique to each individual and changes depending on the activities being engaged in by the amputee. A poorly fitting prosthetic socket can cause significant trauma so it is important to consider how to optimise the fit to maximise the amputee's comfort whilst wearing the limb prosthesis. Current practice in designing a prosthetic socket is time-consuming, and is highly dependent on the experience of the prosthetist. The SocketMaster project aims to integrate micro electronic, mechanical (pressure and acceleration), fluidic biomechanical and moisture sensors into a Master Socket which can help prosthetists to achieve fast customised design and manufacturing of prosthetic sockets for lower limb (trans-femoral and trans-tibial) amputees. Firstly, existing micro sensors such as piezoelectric, MEMS based pressure sensors will be adapted or developed so that pressure distributions within the interface between the residual limb and the socket can be measured. Secondly, a Master Socket will be built by assembling the sensor system in a rigid hosting socket in such a way that the sensors' positions can be adjusted to achieve a comfortable configuration for the patient. The pressure distributions at typical activities of a patient will be used to optimise the socket design to maximise the patient’s comfort. The digital 3D data of the optimised socket design can be fed into a rapid prototyping machine for fast fabrication. Thirdly, clinical trials will be carried out to validate the Master Socket. It is envisaged that SocketMaster will enable same day socket fabrication with optimised quality, and the fit and function of the prosthetic socket will be less dependent on the skills of the prosthetist. |
Original sub-sector | Obfuscated |
Original Currency | USD |
Original budget | 000000000000000 |
Procurement method | Obfuscated Data |
Budget | 000000000000000 |
Location
Region | Obfuscated |
Country | Obfuscated |
State | Obfuscated Data |
County | Obfuscated |
Location | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Source
Source reliability | High |
Data quality score | 100% |
Source | Obfuscated Data |
URL | obfuscated_data,obfuscateddata.com |
More Details
Project Type | Obfuscated Data |
Article Published Date | Obfuscated Data |
