logo

DYnamically MANaged self-cooling HPC Data Centers

Sector: Water Supply and Storage • Location: Spain, Germany, Belgium, Italy, Türkiye

Source: EU Funding & Tenders Portal

Project
Ongoing

DYMAN targets the development of a completely new design of adsorption chillers based on the following innovations (1) New low-temperature adsorbents achieving high capacities at very low driving temperatures below 50 °C. (2) New type of adsorption heat exchangers made of 3D printed structures integrating the adsorption material into a porous structure, which reduces the internal thermal resistanc

Project Information FAQ

Project Information

3 Q
The project “DYnamically MANaged self-cooling HPC Data Centers” is an infrastructure initiative in the Water Supply and Storage sector, located in Spain, Germany, Belgium, Italy, Türkiye. Taiyo aggregates data on it from EU Funding & Tenders Portal.

Want to explore the full details? View the full report

Participants

Sponsoring Agency

Obfuscated Data

Company

Obfuscated Data

Status

Original status

ongoing

Taiyo status

Obfuscated Data

Taiyo last update

00-00-0000

Available timestamps

00-00-0000

Available timestamp type

Obfuscated Data

Contact

Contact name

Obfuscated Data

Phone

0000000000

Email

ObfuscatedData@email.com

Address

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Description

Description

DYMAN targets the development of a completely new design of adsorption chillers based on the following innovations (1) New low-temperature adsorbents achieving high capacities at very low driving temperatures below 50 °C. (2) New type of adsorption heat exchangers made of 3D printed structures integrating the adsorption material into a porous structure, which reduces the internal thermal resistances and improvement of heat transfer by two-phase flow, enhancing the heat transfer rate and reducing the internal electricity consumption of the unit. Additionally the project aims to develop at second core concept to further develop an existing two-phase cooling system, for high-performance computing servers to handle thermal loads more efficiently from next-generation processors. Goals include increasing cooling capacities for processors generating high heat fluxes like the Nvidia H100 chip which produces 70 W/cm2. An additional objective is to recover 50% of waste heat from processors to generate additional cooling power through a sorption heat pump. Combining two-phase cooling directly with heat-powered cooling could significantly improve efficiency over conventional air or water-based cooling methods alone. The objective here is to 1)further develop the present two-phase cooling system to work in an efficient way in combination with the sorption heat pump (concept 1) 2) Development of new evaporator with new advanced surfaces for high heat transfer coefficients (3) Development of new condenser integrated with the heat adsorber of sorption heat pump. This is a crucial component that can improve the efficiency of the whole integrated system to recovery up to 50% of rejected heat. Furthermore, the cooling data center management is a complex engineering system with interactions with different components of the data centers. So, DYMAN proposes a new way of active management of the data center integrating the cooling system as part of the optimization of processor management

Original sub-sector

Obfuscated

Original Currency

USD

Original budget

000000000000000

Procurement method

Obfuscated Data

Budget

000000000000000

Location

Region

Obfuscated

Country

Obfuscated

State

Obfuscated Data

County

Obfuscated

Location

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Source

Source reliability

High

Data quality score

100%

Source

Obfuscated Data

URL

obfuscated_data,obfuscateddata.com

More Details

Project Type

Obfuscated Data

Article Published Date

Obfuscated Data