The Garner Rd. Biosolids facility requires the construction of external mixers on the digester tanks to reduce settling. These external mixers and associated appurtenances will replace the internal mixing system process which has reached the end of its service life. There are three (3) storage tanks that contain 8,000 m³ of sanitary treatment plant sludge each. The sludge must be mixed effectively

Project Information FAQ

Project Information

4 Q
The project “Garner Road Biosolids Management Facility Upgrade - Digester Mixers Replacement - Located in the City of Niagara Falls” is an infrastructure initiative in the Water Supply and Storage sector, located in Ontario, Canada. Taiyo aggregates data on it from Infrastructure Canada.

Want to explore the full details? View the full report

Participants

Sponsoring Agency

Obfuscated Data

Company

Obfuscated Data

Status

Original status

completed

Taiyo status

Obfuscated Data

Taiyo last update

00-00-0000

Available timestamps

00-00-0000

Available timestamp type

Obfuscated Data

Contact

Contact name

Obfuscated Data

Phone

0000000000

Email

ObfuscatedData@email.com

Address

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Description

Description

The Garner Rd. Biosolids facility requires the construction of external mixers on the digester tanks to reduce settling. These external mixers and associated appurtenances will replace the internal mixing system process which has reached the end of its service life. There are three (3) storage tanks that contain 8,000 m³ of sanitary treatment plant sludge each. The sludge must be mixed effectively, otherwise material will settle out and stop the treatment process. The current digester mixing system has significant and ongoing maintenance problems. Not only does this cause problems with the treatment of Biosolids from Regional facilities but in addition to this, the Region has an agreement to supply 5,400 dry tonnes of de-watered biosolids annually to a local firm that produces soil amendment products, which is regulated by the Canadian Food Inspection Agency. When the Region is not able to meet the agreed upon tonnage we must pay the firm $527.37 per ton for the shortage. In summary, Niagara Region is experiencing high maintenance costs and is facing an imminent contractual agreement issue if the mixing system is not replaced.

Original sub-sector

Obfuscated

Original Currency

USD

Original budget

000000000000000

Procurement method

Obfuscated Data

Budget

000000000000000

Location

Region

Obfuscated

Country

Obfuscated

State

Obfuscated Data

County

Obfuscated

Location

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Source

Source reliability

High

Data quality score

100%

Source

Obfuscated Data

URL

obfuscated_data,obfuscateddata.com

More Details

Project Type

Obfuscated Data

Article Published Date

Obfuscated Data