INTEXT 28-32 Derne ST
The status, timeline and source of this project. A free account opens every field.
Source: City of Boston
E -Plan The Elevator Lobby was designed with a minimum dimension of 8 feet. However, an additional wood veneer will be added to the walls, creating a minimum dimension of 7’9”. This dimension and veneer addition can be seen in the diagram attached to the bottom of the letter in the electronic plans attachment. According to Section 403.6.1 of 780 CMR 8th Edition, buildings more than 70 feet in heig
- Status
- Prospective
- Sector
- Road, Commercial, Government
- Location
- Boston, Massachusetts, United States of America
- Updated
- 19 Nov 2026
- Source
- City of Boston
ConstructChat
Ask ConstructChat about INTEXT 28-32 Derne ST
Pick a question to edit it, or write your own.
First answer free · no account
Project Information FAQ
Project Information
Participants
Sponsoring Agency |
Status
Original status | open |
Taiyo status | Prospective |
Taiyo last update | 2026-11-19 |
Contact
| Not available for this record. |
Description
Description | E -Plan The Elevator Lobby was designed with a minimum dimension of 8 feet. However, an additional wood veneer will be added to the walls, creating a minimum dimension of 7’9”. This dimension and veneer addition can be seen in the diagram attached to the bottom of the letter in the electronic plans attachment. According to Section 403.6.1 of 780 CMR 8th Edition, buildings more than 70 feet in height above grade plane must provide a minimum of one fire service access elevator in accordance with Section 3007. Section 3007.4.4 states that the elevator lobby is permitted a minimum dimension of 8 feet. 32 Derne Street is 90 feet in height and therefore must comply with these requirements. The 9th Edition 780 CMR is anticipated to be adopted within the next few months. According to the 9th Edition, and the 2015 IBC, a fire service access elevator is not required unless the building is more than 120 feet in height. The Fifth Floor of 32 Derne Street is new construction and could therefore fall under the 9th Edition. Under the 9th Edition, a fire service access elevator is not required and therefore, the minimum dimension of 7’9” would be permitted. We are requesting to follow the 9th edition for the construction of the Fifth Floor of 32 Derne Street, rather than the 8th edition, as the 9th will soon be adopted. |
Location
Country | United States of America (USA) |
State | Massachusetts |
City | Boston |
Source
Source | City of Boston |
URL |
More Details
Record type | Project |
Sector | Road, Commercial, Government |
Article published date | 2025-08-28 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this project
- News and media coverage
- Technical research
Free account · no card · lands you back on this project
More Road projects in United States of America
- KING STREET IN COHUTTA
- SR 120/ROSWELL RD@CR 4662/EAST COBB DR EXT LT TURN LANE
- DISTRICTWIDE PAVEMENT MARKING DIST 7
- EPHESUS CHURCH ROAD BR.& APPR.@ DOG RIVR(097-02278-00105E)
- CS 1081/GREENVILLE STREET @ CSX RAILROAD IN LAGRANGE
- SR 109 FROM ALABAMA STATE LINE TO SR 14/US 29
- JASPER-DAHLONEGA ROAD
- MOULTRIE - SYLVESTER ROAD