logo
ProjectOpenBP

INTEXT 28-32 Derne ST

The status, timeline and source of this project. A free account opens every field.

Source: City of Boston

E -Plan The Elevator Lobby was designed with a minimum dimension of 8 feet. However, an additional wood veneer will be added to the walls, creating a minimum dimension of 7’9”. This dimension and veneer addition can be seen in the diagram attached to the bottom of the letter in the electronic plans attachment. According to Section 403.6.1 of 780 CMR 8th Edition, buildings more than 70 feet in heig

Status
Prospective
Sector
Road, Commercial, Government
Location
Boston, Massachusetts, United States of America
Updated
19 Nov 2026
Source
City of Boston

ConstructChat

Ask ConstructChat about INTEXT 28-32 Derne ST

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Project Information FAQ

Project Information

5 Q
The project “INTEXT 28-32 Derne ST” is an infrastructure initiative in the Road sector, located in Boston, Massachusetts, United States of America. Taiyo aggregates data on it from City of Boston.

Participants

Sponsoring Agency

Status

Original status

open

Taiyo status

Prospective

Taiyo last update

2026-11-19

Contact

Not available for this record.

Description

Description

E -Plan The Elevator Lobby was designed with a minimum dimension of 8 feet. However, an additional wood veneer will be added to the walls, creating a minimum dimension of 7’9”. This dimension and veneer addition can be seen in the diagram attached to the bottom of the letter in the electronic plans attachment. According to Section 403.6.1 of 780 CMR 8th Edition, buildings more than 70 feet in height above grade plane must provide a minimum of one fire service access elevator in accordance with Section 3007. Section 3007.4.4 states that the elevator lobby is permitted a minimum dimension of 8 feet. 32 Derne Street is 90 feet in height and therefore must comply with these requirements. The 9th Edition 780 CMR is anticipated to be adopted within the next few months. According to the 9th Edition, and the 2015 IBC, a fire service access elevator is not required unless the building is more than 120 feet in height. The Fifth Floor of 32 Derne Street is new construction and could therefore fall under the 9th Edition. Under the 9th Edition, a fire service access elevator is not required and therefore, the minimum dimension of 7’9” would be permitted. We are requesting to follow the 9th edition for the construction of the Fifth Floor of 32 Derne Street, rather than the 8th edition, as the 9th will soon be adopted.

Location

Country

United States of America (USA)

State

Massachusetts

City

Boston

Source

Source

City of Boston

URL

More Details

Record type

Project

Sector

Road, Commercial, Government

Article published date

2025-08-28

More on this project

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this project
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this project