logo

Liquid Dosimetry via Electron Paramagnetic Resonance Spectroscopy

Sector: Water Supply and Storage • Location: Germany

Source: EU Funding & Tenders Portal

Project
Ended

The problem: Lack of water-equivalent dosimeters for radiotherapy Cancer is a global public health problem. Radiotherapy is generally used as an essential method of cancer treatment. Measuring the absorbed dose of radiation to ensure that the radiation delivered to the patient is accurate, is paramount and critical to patient safety, since tumor control and side-effects are highly sensitive to the

Status
Closed
Sector
Water Supply and Storage, Nuclear, Government
Location
Germany
Updated
22 Jul 2026
Source
EU Funding & Tenders Portal

ConstructChat

Ask ConstructChat about Liquid Dosimetry via Electron Paramagnetic Resonance Spectroscopy

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Project Information FAQ

Project Information

4 Q
The project “Liquid Dosimetry via Electron Paramagnetic Resonance Spectroscopy” is an infrastructure initiative in the Water Supply and Storage sector, located in Germany. Taiyo aggregates data on it from EU Funding & Tenders Portal.

Participants

Sponsoring Agency

Status

Original status

ended

Taiyo status

Closed

Taiyo last update

2026-07-22

Contact

Not available for this record.

Description

Description

The problem: Lack of water-equivalent dosimeters for radiotherapy Cancer is a global public health problem. Radiotherapy is generally used as an essential method of cancer treatment. Measuring the absorbed dose of radiation to ensure that the radiation delivered to the patient is accurate, is paramount and critical to patient safety, since tumor control and side-effects are highly sensitive to the applied dose. For this purpose, in-vivo dosimetry (IVD) can be performed as a patient-specific measure of quality control and safety during radiotherapy. Clinical experience and dose prescriptions in radiotherapy have historically been based on the absorbed dose to water. However, when a calibrated dosimeter as for today, which is not water equivalent, is used under non-reference conditions, direct determination of the correct absorbed dose to water is not possible and many detectors show an over-response. Water equivalent dosimeters are not available but particularly desirable in clinical applications. The solution: A small, water-equivalent, non-toxic and liquid dosimeter with electron paramagnetic resonance spectroscopy readout This idea presents an innovative strategy for dose determination using a novel type of liquid, water-equivalent and non-toxic dosimeter with readout via electron paramagnetic resonance (EPR) spectroscopy. This novel liquid EPR dosimeter consists of a small (mm-dimensions) capsuled water-based liquid detector material that can be placed on the patient's skin or in body cavities to measure the delivered dose at relevant locations in clinical situations. The principle presented here is based on a dose-dependent EPR signal loss: Stable paramagnetic species dissolved in aqueous solution are transformed into diamagnetic products upon irradiation. The proposed solution is not an incremental improvement of an existing procedure but an innovative approach making IVD easier to use, cheaper, more accurate – and: water equivalent.

Location

Country

Germany

Source

Source

EU Funding & Tenders Portal

URL

More Details

Record type

Project

Sector

Water Supply and Storage, Nuclear, Government

Article published date

2026-02-15

More on this project

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this project
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this project