Marin Veterans’ Memorial Auditorium Seismic Retrofit & Other Building Systems Improvements
Sector: Commercial • Location: California, United States of America
Source: Marin County Department of Public Works (DPW)
This project will seismically retrofit the Marin Center VMA to mitigate risks to the occupants of facility in the event of a major seismic incident at the site. The improvements are designed to elevate the structural seismic performance to a level that meets the current code standards for life and safety. Project scope of includes strengthening of the theater stage roof diaphragm, strengthening of
Project Information FAQ
Project Information
Want to explore the full details? View the full report
Participants
Sponsoring Agency | Obfuscated Data |
Company | Obfuscated Data |
Status
Original status | active |
Taiyo status | Obfuscated Data |
Taiyo last update | 00-00-0000 |
Available timestamps | 00-00-0000 |
Available timestamp type | Obfuscated Data |
Contact
Contact name | Obfuscated Data |
Phone | 0000000000 |
ObfuscatedData@email.com | |
Address | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Description
Description | This project will seismically retrofit the Marin Center VMA to mitigate risks to the occupants of facility in the event of a major seismic incident at the site. The improvements are designed to elevate the structural seismic performance to a level that meets the current code standards for life and safety. Project scope of includes strengthening of the theater stage roof diaphragm, strengthening of the stage walls, bracing of the suspended control room, and bracing of the plaster ceilings. In addition, the project will include reroofing above the theater stage. While the building has been closed for the Seismic Retrofit project, an Investigative Report was prepared to evaluate the rest of the VMA building structure and systems. The report concluded that the building’s perimeter foundation is structurally sound, and that the elements supporting the domed roof are performing as designed. However, the subgrade below the building has settled significantly. The settlement has damaged the floor slabs, internal sewer and roof drain plumbing, and electrical systems. The report also indicated that the emergency egress lighting system does not meet current code requirements and noted several other electrical and mechanical deficiencies. In order to ensure the VMA is safe for public use when it reopens, a separate project is being planned to address the ground settlement and building systems deficiencies as soon as the work on the Seismic Retrofit project is completed. This will require the building to remain closed through at least the fall of 2025. |
Original sub-sector | Obfuscated |
Original Currency | USD |
Original budget | 000000000000000 |
Procurement method | Obfuscated Data |
Budget | 000000000000000 |
Location
Region | Obfuscated |
Country | Obfuscated |
State | Obfuscated Data |
County | Obfuscated |
Location | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Source
Source reliability | High |
Data quality score | 100% |
Source | Obfuscated Data |
URL | obfuscated_data,obfuscateddata.com |
More Details
Project Type | Obfuscated Data |
Article Published Date | Obfuscated Data |
