Optical Fibre Dose Imaging for Adaptive Brachytherapy
Source: EU Funding & Tenders Portal
ORIGIN aims to deliver more effective, photonics-enabled, brachytherapy for cancer treatment through advanced real-time radiation dose imaging and source localisation. This will be achieved by the development of a new optical fibre based sensor system to support diagnostics-driven therapy through enhanced adaptive brachytherapy. A 16-point optical fibre sensors system will be developed, for Low Do
Project Information FAQ
Project Information
Want to explore the full details? View the full report
Participants
Sponsoring Agency | Obfuscated Data |
Company | Obfuscated Data |
Status
Original status | ended |
Taiyo status | Obfuscated Data |
Taiyo last update | 00-00-0000 |
Available timestamps | 00-00-0000 |
Available timestamp type | Obfuscated Data |
Contact
Contact name | Obfuscated Data |
Phone | 0000000000 |
ObfuscatedData@email.com | |
Address | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Description
Description | ORIGIN aims to deliver more effective, photonics-enabled, brachytherapy for cancer treatment through advanced real-time radiation dose imaging and source localisation. This will be achieved by the development of a new optical fibre based sensor system to support diagnostics-driven therapy through enhanced adaptive brachytherapy. A 16-point optical fibre sensors system will be developed, for Low Dose Rate (LDR) and High Dose Rate (HDR) Brachytherapy, with sensitivity of 150 counts/Gy for LDR- and 2500 counts/mGy for HDR- BT alongside a dedicated data acquisition system providing a dose mapping system with a spatial resolution of 0.5mm (HDR) and 3mm (LDR) and time resolution of 0.1s (HDR) and 0.5s (LDR), with 5% uncertainty. This is a 50% improvement in uncertainty over existing systems. Further interrogation of the optical signal will provide real-time monitoring of the radiation source location during treatment. The ORIGIN system will be integrated into existing clinical brachytherapy treatment planning and delivery systems to confirm that the dose prescribed to the tumour is achieved, whilst ensuring the dose to organs at risk (OARs) is within acceptable limits. This will provide for optimised dose-led, patient-oriented, personalised treatment plans leading to improved patient outcomes and prevention of treatment errors, with the potential to reduce the overall risk of treatment error by 55%. The optical fibre radiation dosimeters will be further optimised for improved optical signal collection efficiency, higher signal-to-noise ratio (SNR) and repeatable high volume fabrication. Taking manufacturability into consideration from the outset will ensure that ORIGIN establishes Europe at the fore of brachytherapy system development and photonics manufacturing. |
Original sub-sector | Obfuscated |
Original Currency | USD |
Original budget | 000000000000000 |
Procurement method | Obfuscated Data |
Budget | 000000000000000 |
Location
Region | Obfuscated |
Country | Obfuscated |
State | Obfuscated Data |
County | Obfuscated |
Location | Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data |
Source
Source reliability | High |
Data quality score | 100% |
Source | Obfuscated Data |
URL | obfuscated_data,obfuscateddata.com |
More Details
Project Type | Obfuscated Data |
Article Published Date | Obfuscated Data |
