COMM - INTERIOR FINISHOUT
-
PROVIDE BROOM CLEAN SPACE FREE OF ALL OTHER TENANTS OR OCCUPANTS WHEN DELIVERED ALL VIOLATIONS.
-
PROVIDE FROM LANDLORD'S CENTRAL PLANT THE EQUIVALENT TO 1 TON OF HVAC FOR EACH 250 SF OF TOTAL SPACE OF THE PREMISES (VAV AND/OR AIR HANDLER UNITS AS APPLICABLE BY TENANT).
-
PROVIDE A COMPLETE ELECTRICAL SERVICE 600 AMP, 277/480 VOLT, 3-PHASE, 4-WIRE ELECTRIC
- Status
- Prospective
- Sector
- Water Supply and Storage, Cement, Waste Processing and Treatment, Metal, Residential, Government
- Location
- Fort Worth, Texas, United States of America
- Updated
- 19 Nov 2026
- Source
- City of Fort Worth Open Data Portal
ConstructChat
Ask ConstructChat about PE16-06876 - Electrical - Finaled
Pick a question to edit it, or write your own.
First answer free · no account
Project Information FAQ
Project Information
Participants
Sponsoring Agency |
Status
Original status | finaled |
Taiyo status | Prospective |
Taiyo last update | 2026-11-19 |
Contact
| Not available for this record. |
Description
Description | COMM - INTERIOR FINISHOUT 1. PROVIDE BROOM CLEAN SPACE FREE OF ALL OTHER TENANTS OR OCCUPANTS WHEN DELIVERED ALL VIOLATIONS. 2. PROVIDE FROM LANDLORD'S CENTRAL PLANT THE EQUIVALENT TO 1 TON OF HVAC FOR EACH 250 SF OF TOTAL SPACE OF THE PREMISES (VAV AND/OR AIR HANDLER UNITS AS APPLICABLE BY TENANT). 3. PROVIDE A COMPLETE ELECTRICAL SERVICE 600 AMP, 277/480 VOLT, 3-PHASE, 4-WIRE ELECTRICAL SERVICE TO THE PREMISES, INCLUDING CONDUIT AND COPPER FEEDER CABLES INSTALLED AND DISCONNECT, SWITCHGEAR, AND METER SOCKET BROUGHT TO WITHIN 25 FEET OF THE LOCATION SHOWN ON THE TENANT'S STUB IN PLANS PROVIDED SUCH PLANS ARE RECEIVED BY LANDLORD AT LEAST 90 DAYS PRIOR TO THE ANTICIPATED DELIVERY DATE OTHERWISE TO THE REAR OF THE PREMISES. 4. PROVIDE SMOOTH LEVEL CONCRETE FLOOR (TO WITHIN 1/4 INCH OVER 100 FEET) THROUGHOUT THE PREMISES READY TO ACCEPT TENANT'S FLOOR COVERING. 5. PROVIDE PLUMBING FOR WATER (1" OR GREATER), SEWER (4"), AND VENT PIPE (3") OR IN LIEU OF A VENT PIPE, A COMMON TOILET EXHAUST VENT STUBBED TO THE REAR OF THE PREMISES. 6. INSTALL A NEW 1-1/2 INCH CONDUIT AND PULL STRING FROM THE MALL PHONE ROOM TO THE REAR OF THE PREMISES FOR PURPOSES OF TELECOMMUNICATIONS EQUIPMENT. LANDLORD WILL USE REASONABLE EFFORTS TO ENSURE THAT THE CLOSETS AND/OR ROOMS WHERE TENANT'S TELECOMMUNICATIONS AND MEDIA CABLES TERMINATE HAVE A DOOR WHICH LOCKS. 7. PROVIDE MINIMUM UNOBSTRUCTED CEILING HEIGHT OF 12'-6" 8. PROVIDE AN INTERIOR CONSTRUCTION BARRICADE LOCATED FOUR (4) FEET OUTSIDE TENANT'S LEASE LINE (UNLESS CODE PRECLUDES THE EXTENSION OF 4 FEET IN WHICH CASE THE BARRICADE WILL BE OUTSIDE OF THE LEASE LINE IN ACCORDANCE WITH CODE) THAT IS TAPED, SANDED, AND PAINTED SEMI-GLOSS WHITE, FITTED WITH ONE (1) SET OF DOUBLE-DOORS, AND TENANT WILL FURNISH AND INSTALL TENANT'S GRAPHICS THEREON. 9. PROVIDE ONE (1) REAR EXIT DOOR THAT IS 44 INCHES WIDE TO ACCEPT DELIVERIES, (PROVIDED SUCH DOOR DOES NOT EXIST). 10. PROVIDE TEMPORARY UTILITIES TO THE PREMISES (LIMITED TO ELECTRICAL AND MALL TILE). 11. SPRINKLER SYSTEM SHUTDOWNS AND FIRE ALARM TIE-INS SHALL BE AT TENANT'S EXPENSE. H & M |
Location
Country | United States of America (USA) |
State | Texas |
City | Fort Worth |
Source
Source | City of Fort Worth Open Data Portal |
URL |
More Details
Record type | Project |
Sector | Water Supply and Storage, Cement, Waste Processing and Treatment, Metal, Residential, Government |
Article published date | 2025-11-07 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this project
- News and media coverage
- Technical research
Free account · no card · lands you back on this project