logo

Protective Equipment for Responders

Sector: Advanced Electronics • Location: United States of America

Source: Grants.gov

Project
Closed

The recipient has successfully developed a PAPR for wildland firefighters that provides HEPA-level protection against particulate matters and Class II NFPA 1984:2022 protection against chemical vapor hazards. In-house testing has been conducted by the recipient to address the work identified under the prior NOFO to include realignment of the WFR’s carbon bed performance in compliance with NFPA 198

Project Information FAQ

Project Information

4 Q
The project “Protective Equipment for Responders” is an infrastructure initiative in the Advanced Electronics sector, located in United States of America. Taiyo aggregates data on it from Grants.gov.

Want to explore the full details? View the full report

Participants

Sponsoring Agency

Obfuscated Data

Company

Obfuscated Data

Status

Original status

closed

Taiyo status

Obfuscated Data

Taiyo last update

00-00-0000

Available timestamps

00-00-0000

Available timestamp type

Obfuscated Data

Contact

Contact name

Obfuscated Data

Phone

0000000000

Email

ObfuscatedData@email.com

Address

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Description

Description

The recipient has successfully developed a PAPR for wildland firefighters that provides HEPA-level protection against particulate matters and Class II NFPA 1984:2022 protection against chemical vapor hazards. In-house testing has been conducted by the recipient to address the work identified under the prior NOFO to include realignment of the WFR’s carbon bed performance in compliance with NFPA 1984:2022, modification of the battery pack to ensure resistance to heat exposure and flammability, and creation of a compartmented backpack for housing of the WFR. Additionally, the wildland firefighter respirator (WFR) has undergone three operational field assessments occurring in FY22/23. The assessments allowed experienced wildland firefighters to participate in various wildland simulation exercises using the WFR. The evaluators provided substantive feedback to the recipient, which was overwhelmingly positive regarding battery life, airflow, noise level, mounting systems, and communication capability while wearing the WFR. These combined efforts have resulted in respiratory technology compliant with the regulatory standards noted in NFPA 1984 and have successfully achieved both functionality and levels of performance that is unavailable from the PAPRs that are currently sold commercially.

Original sub-sector

Obfuscated

Original Currency

USD

Original budget

000000000000000

Procurement method

Obfuscated Data

Budget

000000000000000

Location

Region

Obfuscated

Country

Obfuscated

State

Obfuscated Data

County

Obfuscated

Location

Obfuscated Data, Obfuscated data, obfuscated data, Obfuscated data

Source

Source reliability

High

Data quality score

100%

Source

Obfuscated Data

URL

obfuscated_data,obfuscateddata.com

More Details

Project Type

Obfuscated Data

Article Published Date

Obfuscated Data