Project is rehabilitation and lining of about 360m of existing 750mm sanitary trunk sewer located between Carling Arena (675 Grosvenor St) and Adelaide Street N, and Wallace St and St. James (North and South). This sewer is in poor condition and lining presents a cost effective alternative to replacement. The sewer runs through the rear yards of numerous properties with no access from the street f

Status
Closed
Sector
Water Supply and Storage, Government, Waste Processing and Treatment, Stadium, Road
Location
Ontario, Canada
Updated
22 Jul 2026
Source
Infrastructure Canada

ConstructChat

Ask ConstructChat about Sewer Relining Program Acceleration - Design and Construction

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Project Information FAQ

Project Information

3 Q
The project “Sewer Relining Program Acceleration - Design and Construction” is an infrastructure initiative in the Water Supply and Storage sector, located in Ontario, Canada. Taiyo aggregates data on it from Infrastructure Canada.

Participants

Not available for this record.

Status

Original status

completed

Taiyo status

Closed

Taiyo last update

2026-07-22

Contact

Not available for this record.

Description

Description

Project is rehabilitation and lining of about 360m of existing 750mm sanitary trunk sewer located between Carling Arena (675 Grosvenor St) and Adelaide Street N, and Wallace St and St. James (North and South). This sewer is in poor condition and lining presents a cost effective alternative to replacement. The sewer runs through the rear yards of numerous properties with no access from the street for equipment. Inaccessible for a large portion so little maintenance over the years has led to buildup of debris and calcite, resulting in capacity loss. This work will require Maintenance Hole (MH) modifications to allow for liner to be installed. One MH is in a rear yard on private property. Other rear yard MH’s will be lined through it will be necessary to bury a by-pass pipe in a couple of spots half way across Adelaide and run the main by-pass pipe down the middle lanes of Adelaide St from Wallace St to St James St. This will require the closing of the north and southbound passing lanes for the duration of the lining (one lane of traffic to remain in each direction). The eligible costs are limited to public/municipal property and assets.

Original sector

Drinking Water and Wastewater

Location

Country

Canada

State

Ontario

Source

Source

Infrastructure Canada

URL

More Details

Record type

Project

Sector

Water Supply and Storage, Government, Waste Processing and Treatment, Stadium, Road

Article published date

2026-04-12

More on this project

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this project
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this project