logo
ProjectCompleted

Western Hospital Ventilation Upgrades

Sector: Hospital • Location: Prince Edward Island, Canada

Source: Infrastructure Canada

This project involves upgrades to the current basement ventilation system at Western Hospital to reduce the risks associated with re-occurring humidity problems. This project includes the installation of a new exhaust fan in the basement to maintain a negative air balance in the basement. This fan is to be sized at approximately 1,000 cubic feet per minute (CFM) to provide for a uniform distributi

Status
Closed
Sector
Hospital, Government
Location
Prince Edward Island, Canada
Updated
22 Jul 2026
Source
Infrastructure Canada

ConstructChat

Ask ConstructChat about Western Hospital Ventilation Upgrades

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Project Information FAQ

Project Information

4 Q
The project “Western Hospital Ventilation Upgrades” is an infrastructure initiative in the Hospital sector, located in Prince Edward Island, Canada. Taiyo aggregates data on it from Infrastructure Canada.

Participants

Sponsoring Agency

Status

Original status

completed

Taiyo status

Closed

Taiyo last update

2026-07-22

Contact

Not available for this record.

Description

Description

This project involves upgrades to the current basement ventilation system at Western Hospital to reduce the risks associated with re-occurring humidity problems. This project includes the installation of a new exhaust fan in the basement to maintain a negative air balance in the basement. This fan is to be sized at approximately 1,000 cubic feet per minute (CFM) to provide for a uniform distribution throughout the basement. Install (a) fan coil(s) in the basement with MERV 14 air filtration (to match existing air handling units) approximately 4,500 CFM. Fan coil(s) to have electric or hydronic heating coil and direct expansion (DX) cooling coil arranged and sized to allow for dehumidification within the space below 50% relative humidity (RH) at 20 °C. Provide outdoor DX condenser for fan coil(s). Provide piping and electrical connections for both heating coils and cooling coils and condenser as required. The work will also include cleaning and capping existing systems to allow for this upgrade. The installation of an isolated dehumidification and air filtration system will help to decrease moisture in the basement and remove a condition causing the growth of contaminants in this space. Air exchanges will meet the Canadian Standards Association (CSA) Z317.2 - 2015 standard for outdoor ventilations rates. This project will address operational issues that have been further stressed during the ongoing pandemic and support economic recovery through investment in the community by stimulating construction in central Prince Edward Island.

Original sector

Ventilation Systems

Location

Country

Canada

State

Prince Edward Island

Source

Source

Infrastructure Canada

URL

More Details

Record type

Project

Sector

Hospital, Government

Article published date

2025-10-05

More on this project

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this project
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this project