2026 Calibration of CFS Lab Equipment and Scales

Closed · MITN · Last reported Dec 2025

Source: MITN Purchasing Group

Tender
Closed

Laboratory Equipment / Machines All equipment must be verified full range in the direction specified . The service technician must be fully trained and able to set up and access all proprietary software involved in calibrating and verifying equipment . The service technician must be able to calibrate and adjust

Status
Closed
Location
MITN, United States of America
Updated
3 Nov 2026
Source
MITN Purchasing Group

ConstructChat

Ask ConstructChat about 2026 Calibration of CFS Lab Equipment and Scales

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “2026 Calibration of CFS Lab Equipment and Scales” is a tender record in Taiyo. It is issued for works, goods, or services related to MITN, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Laboratory Equipment / Machines All equipment must be verified full range in the direction specified . The service technician must be fully trained and able to set up and access all proprietary software involved in calibrating and verifying equipment . The service technician must be able to calibrate and adjust devices as needed for verification purposes . All verifications / calibrations must be performed in accordance with applicable sections of ASTM E4 , ASTM D76 , ASTM E74 , and ASTM E467 . All verification / calibration equipment must conform to a quality assurance program meeting ISO / IEC 17025 . Individual reports must be provided for each piece of equipment . Each report must contain the following : Laboratory Name Machine Name Service Date Scales and Balances The service technician must be qualified to calibrate scales to a readability of 0 . 0001g or higher . Some scales / balances require a large amount of weight and must be verified prior to performing calibration . Individual reports must be provided for each piece of equipment . Each report must contain the following : Laboratory Name Machine Name Service Date Linearity Readability As - Found / As - Left with readings taken on eccentricity Standard must be traceable to NIST . Bolt Tension Calibrators Skidmore - Wilhelm brand / model . Individual reports must be provided for each piece of equipment . Each report must contain the following : Laboratory Name Machine Name Service Date Linearity Readability As - Found / As - Left with readings taken on eccentricity Standards must be traceable to NIST .

Location

Country

United States of America (USA)

State

MITN

Source

Source

MITN Purchasing Group

URL

More Details

Record type

Tender

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender