logo

35 X195578 Model 8812 Equipment Shelter

The scope, dates and status of this tender. A free account opens every field.

Source: Pennsylvania Purchasing Group

Tender
Closed

Provide an EKTO brand Model 8812 air monitoring shelter with features specified in this document and in the style supplied to PA DEP in the past . The outside dimensions of the shelter must be eight feet wide by twelve feet long by eight feet high . Specifications include , but are not limited to :

Status
Closed
Sector
Metal, Wind, Steel, Water Supply and Storage, Rail, Manufacturing (Industrial), Seaport, Power Transmission, Power Generation (CCGT)
Location
Pennsylvania, United States of America
Updated
3 Nov 2026
Source
Pennsylvania Purchasing Group

ConstructChat

Ask ConstructChat about 35 X195578 Model 8812 Equipment Shelter

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “35 X195578 Model 8812 Equipment Shelter” is a tender record in Taiyo, linked to the Metal sector. It is issued for works, goods, or services related to Pennsylvania, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Provide an EKTO brand Model 8812 air monitoring shelter with features specified in this document and in the style supplied to PA DEP in the past . The outside dimensions of the shelter must be eight feet wide by twelve feet long by eight feet high . Specifications include , but are not limited to : Provide an EKTO brand Model 8812 air monitoring shelter with features specified in this document and in the style supplied to PA DEP in the past . The outside dimensions of the shelter must be eight feet wide by twelve feet long by eight feet high . Refer to Drawing 4959 - 1 , which is a drawing of an 8x12 shelter with the same specifications listed in this document . All exposed hardware must be galvanized or stainless steel , aluminum or otherwise treated to resist corrosion . The shelter shall be constructed to meet the following requirements : FLOOR ( on skids ): 120 lbs . per square foot uniformly distributed or 3 , 000 lbs . concentrated over any 3 square foot area . Nominal . 040 single - piece aluminum exterior skin laminated to 2 1 / 2 " polystyrene foam slab insulation and 5 / 8 " plywood , finished with 1 / 8 " thick vinyl floor tile or vinyl seamless covering . ROOF : 30 lbs . per sq . foot uniformly distributed or 500 lbs . over any 3 square foot area . Nominal . 040 single piece aluminum exterior skin laminated to 1 / 4 " plywood to form a strong equipment mounting panel using watertight blind threaded inserts . This exterior sandwich is laminated to 2 " polystyrene insulation having a tan aluminum ceiling covering . Shelter roof is designed for personnel traffic and will be standard roof rubber coating that is non - skid . Roof shall have a slant along the 12 ’ dimension with a rise of 2 - 1 / 2 inches from the short wall to the tall wall . The tall wall shall be on the roof access ladder side . MOBILITY : The shelter will withstand dynamic loadings as encountered during normal transport via trailer , railroad , aboard ship , air lift , forklift and crane handling . STRUCTURAL : Wind loadings up to 125 MPH . Seismic Zone 4 ( Note : Shelter , when commercially transported , will withstand up to 8G ’ s ). WALLS & DOOR : Nominal . 040 prefinished baked - on light tan polyester aluminum exterior / interior skins laminated to 2 " polystyrene slab insulation ( R - 12 ). MEMBERS : All panel members are formed 16 - gauge aluminum " hat " sections , 24 ” on center metal framing ; Shelter Specifications 4 / 14 / 2025 ; 1 ; PANEL ASSEMBLY : All shelter panels are vacuum - bonded , using high strength epoxy adhesive . Exterior skins are further riveted to panel members . SHELTER ASSEMBLY : Panels are jointed together with . 125 or . 180 thick aluminum corner angles with 3 / 16 " & 1 / 4 " closed end watertight blind rivets . All shelter joints are sealed with silicone caulking compound , remaining flexible after cure and providing a weather tight unit . SHELTER SKIDS : Two 2 " wide x 3 " high skids , longitudinal on shelter exterior floor . Skids are pre - drilled for trailer bolt down . These skids MUST be pre - drilled , and the shelter must be capable of bolt down onto an EKTO brand Model TR - 1 transport trailer . The shelter MUST meet the load handling capacity of this trailer . See Appendix C for Skid specifications . LIFT / TIE DOWN / LEVELING PROVISION : Four ( 4 ) lift and tie down rings mounted on the shelter floor bottom . Shelter tie down shoes are not needed . Each shelter bottom corner shall contain adjustable leveling tie down pads ( 8 inches sq .) with a total maximum adjustment of 4 inches . JACK LIFTS : Upper and lower jack mounts , mounted on each corner , are to provide for lifting and leveling capability when utilizing EKTO Manufacturing lifting jacks . The lower mount shall be welded to the large jack corner pockets ( on the right - and left - hand sides of the shelter ). Leveling Tie Down Pads shall not interfere with jack operation . DOOR : One main entrance door 36 " wide x 80 " high at the location shown in Drawing 4959 - 1 , fully gasketed , with cam - type door latch and padlock . Inside safety release when door is padlocked from the outside . Three heavy - duty chrome plated door hinges and hydraulic door closure . ( A doorknob or any integral locking mechanism is NOT acceptable ). A doorstop which holds the door open ( approximate 100 - degree angle ) must be provided . The Commonwealth will provide the padlock . SHELTER FINISH : All wall panel exterior / interior skins are pre - finished , baked - on light tan polyester coated , for long lasting life , abrasion and chip resistance . Shelter corner angles and caps are bare aluminum of an alloy type to resist corrosion and staining . Exposed hardware is either stainless - steel , zinc , cadmium or chrome plated to resist corrosion . Roof coated with rubber compound , nonskid . The shelter must have a 30 " wide , desk height workbench installed along the left 8 ’ wall . This workbench must have a 2 1 / 2  radius seed port every two ( 2 ) feet ( total of 5 ports ) for computer and equipment cables ( see Drawing 4959 - 1 ). The workbench shall be designed in such a way so there is 60 - 1 / 2 " from the ceiling to the bench top for entire length of the bench . All electrical components , hardware and wiring conform to the requirements of the NATIONAL ELECTRICAL CODE ( NEC ). Shelter must be pre - wired with a minimum 100 - amp service and shall contain the necessary hardware to allow the service wire to enter the housing and be hardwired through the top of the service panel ( 100 Amp , 240 / 208 shunt main breaker ). Electric service entrance shall be ground fed , LB - type ( do not supply a mast nor weather head ). Consideration should be given to the location of the tower , the ground fed service entrance , and any outside GFIC receptacles , so that they do not interfere with their respective operations . All shelter internal wiring will be enclosed in surface mount raceways ( Wiremold ) and conduits . The exterior shell and all internal metallic components are to be electrically grounded via a grounding lug for safety ( hook - up to grounding rod by others ). Internal electrical components and outlets are grounded via a separate ground wire in addition to the metallic conduit and raceway grounding system . External utility outlets are wired to a ground fault protector - type circuit breaker . The following circuit breakers and outlets must be provided : Two 20 - amp circuits with two duplex outlets each must be provided at workbench height along the 12 ' workbench wall . One 20 - amp circuit with three duplex outlets must be provided along the rear 8 ' wall . One 20 - amp circuit with three duplex outlets must be provided under the workbench . One 20 - amp circuit with four duplex outlets ; one outlet installed on the remaining 8 ' ( Smart Room Air Conditioner ) wall and 3 duplex outlets installed on the remaining 12 ’ wall . Two exterior 20 - amp circuits with 2 GFIC duplex receptacles ( one for each circuit ) must be provided . 20 - amp GFIC duplex receptacles to be installed on the outside rear wall . The placement of these two outlets should not interfere with the operation of the meteorological tower or main electrical feed . One 15 - amp circuit with one duplex receptacle installed near the blower motor on the rear wall of the housing . Other circuits , switches and outlets necessary for general station operation must also be provided ( e . g ., air conditioner , lighting , etc .) Interior fluorescent lighting controlled by an interior switch beside the door must be provided . A temperature control system , consisting of a recent model wall mount 240V Smart Room Air Conditioner . This Unit will provide cool and heat through this unit . The Smart Air conditioner is to be mounted through the same wall as door . The opening to receive the smart room air conditioner must not be smaller than 15 - 1 / 8 " x 19 - 3 / 4 ". Each shelter must contain a sampling manifold consisting of the following parts and hardware : 25 mm Air Sampling Cane , Funnel Type ( ACE Glass Part No . 7493 - 12 ) 25 mm Ace Glass Cane Extension ( ACE Glass Part No . D167200 ) 25 mm glass sampling manifold 39 inches long , with 8 ports ( ACE Glass Part No . D136901 ) Glass tee ( ACE Part No . 7495 - 06 ) Water trap bottle ( ACE Part No . 7501 - 11 ) Manifold blower ( ACE Part No . 7511 - 10 ) Roof attachment ( ACE Part No . 7508 - 06 ) Misc . items : Mounting hangers ( ACE Part No . 8862 - 03 ) Bleed adapter ( ACE Part No . 7499 - 21 ) Blower mount ( ACE Part No . 7509 - 09 ) Five ( 5 ) Nylon bushings with FETFE O - rings ( ACE Part No . 7506 - 10 ). The sampling cane must enter through the shelter roof in the left rear corner ( as one enters the shelter ). The manifold must traverse the rear wall within one foot of the ceiling and the blower must exhaust through the rear shelter wall . The cane , tee , bottle , manifold , bleed adapter must all be easily removable for cleaning . The glass tee is not to be connected directly to the nylon roof attachment . Excess threads of roof attachment that protrude into the interior space may be cut . Water bottle must be easily removed from wall bracket . In the lower right rear corner , the shelter must contain six 1 / 4 - inch stainless steel Swagelok bulkhead fittings to allow sensors to be exhausted from the shelter interior .

Location

Country

United States of America (USA)

State

Pennsylvania

Source

Source

Pennsylvania Purchasing Group

URL

More Details

Record type

Tender

Sector

Metal, Wind, Steel, Water Supply and Storage, Rail, Manufacturing (Industrial), Seaport, Power Transmission, Power Generation (CCGT)

Article published date

2026-05-09

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender