35-X196718 Gas Chromatographs (GCs)
Closed · Pennsylvania
Source: Pennsylvania Department of Transportation (PennDOT)
GAS CHROMATOGRAPH WITH FLAME IONIZATION DETECTORS FOR USE WITH EPA PHOTOCHEMICAL ASSESSMENT MONITORING STATION PROGRAM The Department of Environmental Protection (DEP), Division of Air Quality Monitoring, is seeking two (2) gas chromatographs (GCs) configured to use for the EPA PAMS Program, a minimum list of compounds to be monitored are listed in Table 1 at the end of Section 1. A system based o
- Status
- Closed
- Sector
- Geothermal, LNG, Hydrogen, Power Generation (CCGT), Fertilizers
- Location
- Pennsylvania, United States of America
- Updated
- 3 Nov 2026
- Source
- Pennsylvania Department of Transportation (PennDOT)
ConstructChat
Ask ConstructChat about 35-X196718 Gas Chromatographs (GCs)
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | GAS CHROMATOGRAPH WITH FLAME IONIZATION DETECTORS FOR USE WITH EPA PHOTOCHEMICAL ASSESSMENT MONITORING STATION PROGRAM The Department of Environmental Protection (DEP), Division of Air Quality Monitoring, is seeking two (2) gas chromatographs (GCs) configured to use for the EPA PAMS Program, a minimum list of compounds to be monitored are listed in Table 1 at the end of Section 1. A system based on the Perkin Elmer Clarus 590 is requested. The system is to be configured for use with helium carrier gas, to be provided by DEP. Hydrogen and zero air generators capable of supplying the flame ionization detectors must be included in the bid. The thermal desorption preconcentrator shall use a thermo-electric chiller or other technology that does not require a consumable cryogen such as liquid nitrogen. The system is expected to follow the EPA PAMS Program sampling schedule of collecting and analyzing an air sample every hour continuously with a data completion goal of 75% or better for continuous operation. Any technical questions should be directed to Charles Prettner, phone: 717-787-7563 email: chprettner@pa.gov Email communication is preferred. b. Questions regarding bidding procedures should be directed to Brian Franklin, phone: 717-787-2471, email: brfranklin@pa.gov. Email communication is preferred. |
Location
Country | United States of America (USA) |
State | Pennsylvania |
Source
Source | Pennsylvania Department of Transportation (PennDOT) |
URL |
More Details
Record type | Tender |
Sector | Geothermal, LNG, Hydrogen, Power Generation (CCGT), Fertilizers |
Article published date | 2026-09-24 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Geothermal tenders in United States
- Thermal Laminating Film for Jordan School District Central Warehouse (One-Time Purchase)
- 143936 RS-P & RS-E THERMAL AND PHYSICAL CAMERAS
- 146014 CAMERA, THERMAL IMAGING
- 143936R1 RS-P & RS-E THERMAL AND PHYSICAL CAMERAS
- FLIR T1020 HD Thermal Camera Kit
- 23BLE Athlon Thermal Devices
- Night Vision Monoculars
- Thermal recovery Systems - Phoenix Controls
