logo

6130--Uninterruptible Power Supply (Ups) For Pharmaceutical Refrigerators

Sector: Power Generation (CCGT) • Location: Indianapolis, East Indianapolis VA Clinic 9402 East 21st Street, Indianapolis

Source: SAM.gov

Tender
Sources Sought

SOURCE SOUGHT NOTICE - Uninterruptible Power Supply (UPS) for VA Medical Clinic This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement described below. The purpose of this notice is to assess industry interest and identify potential sources with the capabilities and qualifications to meet the following requirements.

Status
Prospective
Sector
Power Generation (CCGT), Power Transmission, Residential, Manufacturing (Industrial), Road, Commercial, Hospital
Location
Indianapolis, East Indianapolis VA Clinic 9402 East 21st Street, Indianapolis
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about 6130--Uninterruptible Power Supply (Ups) For Pharmaceutical Refrigerators

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “6130--Uninterruptible Power Supply (Ups) For Pharmaceutical Refrigerators” is a tender record in Taiyo, linked to the Power Generation (CCGT) sector. It is issued for works, goods, or services related to Indianapolis, East Indianapolis VA Clinic 9402 East 21st Street, Indianapolis.

Participants

Not available for this record.

Status

Original status

sources sought

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

SOURCE SOUGHT NOTICE - Uninterruptible Power Supply (UPS) for VA Medical Clinic This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement described below. The purpose of this notice is to assess industry interest and identify potential sources with the capabilities and qualifications to meet the following requirements. This is not a solicitation for proposals. No contract will be awarded from this notice. No proposals are being requested or accepted with this notice. REQUIREMENT The agency is seeking information on domestic sources of supply for two types of Uninterruptible Power Supply (UPS) backups with salient characteristics described below: Type One Quantity 3 ea. Shall have at least 2000 Watts Output Shall have minimum surge capacity of 4,000 watts Made in America Must include at least 2 120V NEMA 5-20 duplex receptacles Dimensions cannot exceed be 91 H X 14 W X 10 D ±6 , in any direction Shall have single-phase 120 VAC, 60 Hz output Shall be capable of providing 88 hours of running time for a single half-size pharmaceutical refrigerator Shall be designed for operation in healthcare environments Automatic backup power activation transfer time shall be less than 20 milliseconds Shall be designed for indoor installation Must be capable of being wall mounted due to space limitations in the medication alcoves Shall provide a pure sine wave output suitable for medical-grade refrigeration, electronic controls, monitoring systems, and other sensitive healthcare equipment. Shall operate from a standard 120 VAC, 20-amp utility circuit and shall utilize a NEMA 5-20P connection or equivalent. Type Two Quantity 1 ea. Shall have at least 3000 Watts Output (Qty = 1) Shall have minimum surge capacity of 6,000 watts Made in America Must include at least 2 120V NEMA 5-20 duplex receptacles Dimensions cannot exceed 91 H X 55 W X 10 D ±6 any direction Shall have single-phase 120 VAC, 60 Hz output Shall be capable of providing 88 hours of running time for a single full-size pharmaceutical refrigerator Shall be designed for operation in healthcare environments Automatic backup power activation transfer time shall be less than 20 milliseconds Shall be designed for indoor installation Shall provide a pure sine wave output suitable for medical-grade refrigeration, electronic controls, monitoring systems, and other sensitive healthcare equipment. Shall operate from a standard 120 VAC, 20-amp utility circuit and shall utilize a NEMA 5-20P connection or equivalent. Interested parties who can provide the products described are requested to submit the following information: Company name, address and point of contact with phone number, SAM Unique Entity Identifier (UEI), Product information documenting salient characteristics, Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc., Place of manufacture, Any other pertinent company documentation. Note: All interested parties must be registered in SAM (System for Award Management) to be eligible for the award of a Government contract. Send submissions via email to Brian.Rosciszewski@VA.gov., reference 36C25027Q0037 is email subject. Firms that respond to this Sources Sought notice but do not provide ALL the requested information may not be considered by the Government when making acquisition decisions. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. Respondents may not be notified of the results of this notice; it is at the discretion of the Government to release any results. ** End of Sources Sought Notice **

Original sector

Not Identified

Location

Country

East Indianapolis VA Clinic 9402 East 21st Street, Indianapolis

City

Indianapolis

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Power Generation (CCGT), Power Transmission, Residential, Manufacturing (Industrial), Road, Commercial, Hospital

Article published date

2026-10-16

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender