6515 -- NX EQ Hand Drills Foot Care ( VA - 26 - 00041528 )
One of 10,000+ tenders Taiyo tracks in Maryland.
Source: Maryland Purchasing Group
DESCRIPTION The Veterans Health Administration ( VHA ) Non - Expendable Equipment National Program has identified Hand Drills , Foot Care product line as a candidate for a VA - wide ( otherwise referred to as national ) single Requirements contract award . The Department of Veterans Affairs ( DVA ) Office of Procurement ,
- Status
- Closed
- Sector
- Water Supply and Storage, Warehouse, Government, Manufacturing (Industrial), Commercial, Residential, Hospital
- Location
- Maryland, United States of America
- Updated
- 3 Nov 2026
- Source
- Maryland Purchasing Group
ConstructChat
Ask ConstructChat about 6515 -- NX EQ Hand Drills Foot Care ( VA - 26 - 00041528 )
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | DESCRIPTION The Veterans Health Administration ( VHA ) Non - Expendable Equipment National Program has identified Hand Drills , Foot Care product line as a candidate for a VA - wide ( otherwise referred to as national ) single Requirements contract award . The Department of Veterans Affairs ( DVA ) Office of Procurement , Acquisition and Logistics ( OPAL ) Strategic Acquisition Center ( SAC ) on behalf of VHA is issuing this Request for Information ( RFI ) in accordance with the FAR 10 . 001to determine the availability and technical capabilities of qualified sources . The period of performance will consist of a base of 12 - months with four 12 - month option periods from the date of award . The SAC in conjunction with VHA is seeking a qualified source to manufacture Hand Drills , Foot Care on an agency wide basis . VA intends to award a Brand Name or Equal ( BNOE ) single award Requirements contract for this requirement IAW with FAR 16 . 503 . Vendors will be required to deliver Hand Drills , Foot Care to VA medical centers and facilities throughout the United States . The anticipated period of performance is for one ( 1 ) 12 - month base period with four ( 4 ) 12 - month option periods from the date of award . However , the Government ' s decision as to whether or not to continue with the contract , upon annual review , will be based upon successful performance during each previous year and continued need . The Contractor must demonstrate the ability to meet all requirements for the solicitation . The associated North American Industrial Classification System ( NAICS ) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees . The FAR Provision found at 52 . 204 - 7 ( b )( 1 ) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal . You may access the SAM website at Home | SAM . gov . All offerors must be certified with the appropriate NAICS code on the SAM website . All SDVOSB / VOSB offerors must be verified in the Small Business Administration ( SBA ) database at Veteran Small Business Certification ( VetCert ) database at : Veteran Small Business Certification ( sba . gov ) at the time of proposal submission . This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract , nor does the Government intend to pay for any information submitted as a result of this notice . This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near - term abilities . The information provided herein is subject to change and in no way binds the Government to solicit for , or award , a competitive contract . It is emphasized that this is a notice solely for planning and informational purposes . 2 . 0 SCOPE The Veterans Health Administration ( VHA ) Non - Expendable Equipment National Program has identified the Hand Drills , Foot Care product line as a candidate for a VA - wide ( otherwise referred to as national ) contract . Hand Drills , Foot Care are handheld instruments designed to hold and provide rotatory movement ( i . e ., torque ) to integral or detachable burs that are used for foot care . Foot care hand drills consist of high - speed powered ( e . g ., electric ) instruments that typically include a control unit and an attached handpiece with a chuck and work with detachable components such as burs and polishing devices . Foot care hand drills are intended primarily for debriding callous and other hard tissue and also for shaping the toenails during therapeutic or cosmetic procedures ; some dedicated burs also permit use under the nails . Foot care hand drills are not usually intended for nail care ; they frequently include irrigation and / or vacuum suction capabilities . The following Contract Line Items are being considered : Contract Line Items Manufacturer Part Number Description 0001 Medicool VACFILE - CL Pro Vac File ® Classic for Podiatry 0002 Medicool YVFC - 00 Pro Vac File ® Classic Hand Piece with Hose Only for Podiatry 0003 Medicool VACFILE Pro Vac File ® for Podiatry 0004 Medicool YVF - 00 Pro Vac File ® Replacement Hand Piece with Hose Only for Podiatry 0005 Medicool FILESTRM - 1 - P File Stream System for Podiatry 0006 Medicool YFST - 00 File Stream Replacement Hand Piece with Hose Only for Podiatry 0007 Medicool FILESPRY - 1 - P - 1 File Spray 0008 Medicool FILESTR - F1 Variable Speed Foot Control The Department of Veterans Affairs ( VA ) is seeking vendors who can provide Medicool  ® Hand Drills , Foot Care or equal as listed above which meet all the following salient characteristics . Vendors may quote any product solution or configuration so long as they meet the salient characteristics . Products quoted in the technical volume must be captured on the Vendor s pricing volume ( Attachment A , Price Cost Schedule ) of the solicitation . Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution ; these items must be captured in the Vendor s pricing volume with a quantity of zero . Vendors shall provide descriptive literature which will be used to thoroughly evaluate each proposal to determine the extent to which it meets the Salient Characteristics ( SCs ) listed in the Combined Synopsis / Solicitation Notice . Vendors are required to complete the highlighted area on the SCs Chart located on the Combined Synopsis / Solicitation document listing the location where compliance to the SCs can be found . The chart must be included with the vendor s submission . Offers which do not include this complete chart will not be considered for award . CLIN s 0001 , 0003 , 0005 , 0007 apply to the following SC s SC # SALIENT CHARACTERISTICS SC Literature Map SC 1 Drill Speed ( rpm ) 30 , 000 or greater Medicool Page 2 , 4 , 6 , 8 Podotronic Page 1 - 2 SC 2 Has Variable Speed Control Page 2 , 4 , 6 , 8 Page 1 - 2 CLIN s 0001 , 0003 , 0005 , apply to the following SC s SC # SALIENT CHARACTERISTICS SC Literature Map SC 3 Has foot control capability Medicool Page 4 , 10 Podotronic Page 3 SC 4 Utilizes filter Page 2 , 4 , 6 Page 1 SC 5 Integrated Vacuum Page 2 , 4 , 6 Page 1 SC 6 Able to utilize 3 / 32 ( 2 . 35mm ) burs Page 2 , 4 , 6 Page 1 CLIN 0007 applies to the following SC s SC # SALIENT CHARACTERISTICS SC Literature Map SC 7 Brushless motor Medicool Page 8 Podotronic Page 2 SC 8 Integrated spray handpiece Page 8 Page 2 SC 9 Integrated water reservoir Page 8 Page 2 Evaluation Sub - factors Design Design features and functions of the offered device will be evaluated . Areas include but are not limited to the following : Lightweight handpiece Built - in Burr Holder Hand piece lights Performance The Device will be evaluated for its ability to perform its intended function . Areas include but are not limited to : Motor Operation Forward / Reverse Safety The device will be assessed for patient safety features , including , but not limited to , the following areas : Level of filtration HEPA preferred Quality / Construction / Training Warranty Service Maintenance For each product ( brand name and part number ), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above . The Government ' s intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer ( OEM ) and as clinically required . Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs . Additionally , responses can include any additional product that may be beneficial . These items must be clearly identified by brand name and part number . Responses to this Sources Sought Notice shall include the following : Does vendor offer an annual service plan , Yes or No ? If Yes : What does the plan cover ? Does plan cover software updates only ? Does the plan cover parts repair or replacement only ? Does the plan cover both software and parts ? If applicable , vendors are requested to provide documentation that shows information on their service plan . Is the service provided by the OEM or a subcontractor ? Full name and address of company SAM Unique Entity Identifier ( UEI ) / CAGE Code Business Size Manufacturer or Distributor If the distributor , provide manufacturer s full name , business size and address . Country of Origin designation for all products . Ability to provide uninterrupted supply of products on a national scale . Technical Literature that clearly shows product ( s ) meet the identified salient characteristics and page numbers where each salient characteristic is met . Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified . Authorized Distributor Letter Certified by OEM with a current date . Although not required , vendors responding to this Sources Sought may also submit a Capabilities Statement . Contractors submitting capability statements in response to this RFI must specifically address the questions outlined above . Generic capability statements that do not directly pertain to this RFI will not be considered . Additionally , links requesting capability statements or further information will not be accessed . All responses must be submitted as an actual file attachment . |
Location
Country | United States of America (USA) |
State | Maryland |
Source
Source | Maryland Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Warehouse, Government, Manufacturing (Industrial), Commercial, Residential, Hospital |
Article published date | 2026-05-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Water Supply and Storage tenders in United States of America
- Wastewater Capital Plan Delivery - Program Management Consultant
- As-Needed Health and Safety Rescue Related Training
- As-Needed Wastewater and Stormwater Services
- Southeast Water Pollution Control Plant (SEP) Program Construction Management (CM) Services
- Re-Bid: Collection System Division - External Audit of the Environmental Management System
- Demonstration Garden Operation and Educational Programming (7th and Lawton)
- Sidewalk Garden Project
- As-Needed Engineering Design Services
