6515 -- TONOMETER ( Band Name or Equal )
Bids closed Mar 2026 · Wisconsin · Last reported Mar 2026
Source: Wisconsin Purchasing Group
THIS IS A SOURCES SOUGHT NOTICE ONLY . THIS IS NOT A REQUEST FOR QUOTE . Â The NCO 12 , Great Lakes Acquisition Center , 115 S . 84th Street , Suite 101 , Milwaukee , WI 53214 , is performing market research to determine if there is a sufficient number of qualified : ( 1 ) Service - Disabled Veteran Owned Small
- Status
- Closed
- Sector
- Power Generation (CCGT), Government, Manufacturing (Industrial), Commercial, Residential, Hospital, Road
- Location
- Wisconsin, United States of America
- Updated
- 3 Nov 2026
- Source
- Wisconsin Purchasing Group
ConstructChat
Ask ConstructChat about 6515 -- TONOMETER ( Band Name or Equal )
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | THIS IS A SOURCES SOUGHT NOTICE ONLY . THIS IS NOT A REQUEST FOR QUOTE .  The NCO 12 , Great Lakes Acquisition Center , 115 S . 84th Street , Suite 101 , Milwaukee , WI 53214 , is performing market research to determine if there is a sufficient number of qualified : ( 1 ) Service - Disabled Veteran Owned Small Business ( SDVOSB ); ( 2 ) Veteran Owned Small Business ( VOSB ); or ( 3 ) Small or emerging small business firms , or ( 4 ) Other Than Small business firms , to provide a Brand Name or Equal TONOMETER to the Tomah VA Medical Center 500 E . Veterans Street Tomah , WI 54660 - 3105 .  Brand Name : TONOMETER - II , ARK WITH TONOMETRY DESCRIPTION OF SUPPLIES Manufacturer Manufacturer Part No QUANTITY TONOMETER - II , ARK WITH TONOMETRY NIDEK TONOMETER - II , ARK WITH TONOMETRY 1 General Requirements : Salient Characteristics : ( Brand Name or Equal ) Refraction measurement range must be no less than - 30 . 00D TO + 25 . 00D ( Spherical ) and 0 . 00D to  ± 12 . 00D ( cylindrical ) Keratometry measurement range must be no less than 5 . 00mm to 13 . 00mm in radius curvature Intraocular Pressure Range shall be From 7mm to 60mmHg Axis SHALL BE NO LESS THAN 0 ° to 180 ° ( 1 °/ 5 ° increments ) Minimum Measurable Pupil Diameter SHALL NOT BE LESS THAN 2mm Radius Curvature Range must be no less than 5 . 00 to 13 . 00mm ( 0 . 01mm increments ) Corneal Refractive Power shall not be less than 25 . 96D to 67 . 50D ( n = 1 . 3375 ), ( 0 . 01 / 0 . 12 / 0 . 25D increments ) Must be able to Auto Track & Automatic Data Capture X - Y - Z direction , Automatic Data Capture PD Measurable range no less than 30 . 00mm to 85 . 00mm ( indication increments : 1mm ) Corneal Size ( CS ) range shall be no less than 8 . 1mm 14 . 6mm ( indication increments : 0 . 1mm ) Pupil Size ( PS ) range shall be no less than 0 . 8mm 12 . 1mm ( indication increments : 0 . 1mm ) NON - CONTACT TONOMETER : Must be able to measure from 1mm Hg to 60mm hg Working distance no less than 11 . 0mm Must include inner fixation light All interested firms who can meet the requirements stated above should respond , in writing , INCLUDING ALL THE FOLLOWING : Company name . Address . Point of contact ( name / title / telephone number / e - mail address ). FSS / SEWP Contract number , if applicable . UIE number . Tax ID number . Indication of which business category ( SDVOSB , VOSB , Small Business or Other Than Small Business ) for which the organization qualifies . A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above . Documentation from manufacturer ( i . e . correspondence from manufacturer ) of your firm being an authorized distributor for the manufacturer .  Submit responses to the Contracting Specialist , Waymon McNeal , at Waymon . McNealjr @ va . gov no later than 3 : 00 PM ( Central Standard Time ), 11 March 2026 .  36C25226Q0316 TONOMETER shall be referenced on all correspondence regarding this announcement .   TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED .  The NAICS Code 339112 Surgical and Medical Instrument Manufacturing , is applicable to this acquisition ; the size standard is 1000 employees . Interested firms are reminded that in accordance with FAR 4 . 12 , prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4 . 11 required registration in the Systems for Award Management ( SAM ) database prior to award of a contract . The Government will use responses to this notice to make an appropriate acquisition decision . This is the only notice ; no other copies of this notice will be provided .   |
Location
Country | United States of America (USA) |
State | Wisconsin |
Source
Source | Wisconsin Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Power Generation (CCGT), Government, Manufacturing (Industrial), Commercial, Residential, Hospital, Road |
Article published date | 2026-05-06 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Power Generation (CCGT) tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Security Hardware Services
- 23B49SR Marine Science Center Turtle Canopy
- Purchase and Supply of Engine Oil for the McIntosh Reciprocating Engine Project MREP
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- PreQualification of Bidders for Chaboya Improvements
