logo

6515--Bronchoscopes Intent To Sole Source

Sector: Water Supply and Storage • Location: United States of America

Source: SAM.gov

Tender
Special Notice

NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs (VA) hereby provides notice of its intent to award a sole-source, firm-fixed-price contract to Olympus America Inc. for an upgrade to an existing Olympus bronchoscopic system currently in use by the Government. The Bronchoscopes are manufactured in Japan a TAA-designated country. The Buy American Act is not applicable to this procu

Status
Closed
Sector
Water Supply and Storage, Power Generation (CCGT), Hospital, Manufacturing (Industrial), Government, Commercial, Residential
Location
United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about 6515--Bronchoscopes Intent To Sole Source

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “6515--Bronchoscopes Intent To Sole Source” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to United States of America.

Participants

Not available for this record.

Status

Original status

special notice

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs (VA) hereby provides notice of its intent to award a sole-source, firm-fixed-price contract to Olympus America Inc. for an upgrade to an existing Olympus bronchoscopic system currently in use by the Government. The Bronchoscopes are manufactured in Japan a TAA-designated country. The Buy American Act is not applicable to this procurement. Olympus America Inc. is the Original Equipment Manufacturer (OEM) and has confirmed that they do not have any authorized distributors. All sales, upgrades, and replacements for this system must be provided directly by Olympus. Therefore, this represents a sole source requirement under FAR 6.302 1 (Only One Responsible Source). The Contracting Officer does not wish to receive phone calls regarding this requirement. Interested parties may identify their interest and capability to respond only via email. Responses must be submitted by email to Marcus.Lewis2@va.gov no later than March 12, 2026, 10:00 am. Any responses received will be evaluated solely to determine whether to conduct competitive procurement. This is not a request for competitive proposals and a solicitation will not be issued. However, all information received by the response deadline will be considered by the Government. STATEMENT OF NEED GENERAL: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. BACKGROUND: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. The currently used BF-UC180F ultrasound bronchoscopes are at end-of-life, and Olympus is coming to an end to their support of this model. PURPOSE: These scopes are used in the Bronchoscopy procedure rooms to provide video imaging during bronchoscopy procedures. SCOPE: James A. Haley VA Hospital is requesting contractors provide brand name only equipment that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment features are essential to the technical requirements to meet the needs of the government. SALIENT CHARACTERISTICS: Must be compatible with current video processing system (Olympus) used in all suites Must be able to be cleaned and reprocessed using the current equipment owned by SPS Provides enhanced access and control to allow staging and diagnosis of even difficult-to-reach lymph nodes and lesions. Real-time ultrasound imaging enables direct visualization of the ViziShot 2 EBUS-TBNA needle as it penetrates the lymph node. This facilitates correct capsule-to-capsule technique, which helps to optimize sample collection, and provides clearer procedural views: an integrated water jet channel helps maintain clear views during procedures The uniquely designed compact distal tip of the BF-UC190F and increased scope angulation enhances maneuverability with better access to difficult-to-reach lymph node stations in the mediastinum (4L) and in the hilum (10R). A decreased forward oblique angle of 20° facilitates easier endoscopic orientation and allows the operator to keep the endoscopic image in full field of view while navigating the airways during a procedure. Dual Focus allows the user to select between two focus settings. A steeper needle puncture angle provides a more perpendicular needle orientation toward the target allowing for smoother target penetration between cartilage rings and other critical vessels. An improved endoscopic image with higher resolution provides better visualization in the airway to accurately identify anatomy landmarks and detect abnormalities. Wider/Increased Viewable Angle: Wider the field of view to attain an increase viewable distance. The power of the EVIS EXERA III platform expands across the hospital to enable equipment standardization and simplified support and service, with the ultimate goal of lowering the total cost of equipment. The BF-UC190F has a working channel of 2.2 mm that is compatible with a full line-up of Olympus EBUS-TBNA needles which are designed to deliver outstanding performance while minimizing channel damage, thereby potentially reducing repair costs and extending endoscope life. TRADE: Trade-in value will be provided in for Olympus BF-UC180F ultrasound bronchoscopes currently on hand. Serial Numbers as follows: 7621602; 7621606; 7621611; 7621612. SOFTWARE: Compatibility with EndoSoft/ProvationMD softwares, and CPRS/Vista. TRAINING: Government will not require additional training. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered and installed within 30 days of receipt of purchase order, and no later than 4/30/2026. PLACE OF Delivery: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd. Bldg 1, Tampa, Florida 33612, between 8:00AM to 4:30PM. Delivery during the Holiday will not be accepted.

Original sector

Not Identified

Location

Country

United States of America (USA)

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Power Generation (CCGT), Hospital, Manufacturing (Industrial), Government, Commercial, Residential

Article published date

2026-02-27

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender