logo

735 Ams Hvac

Sector: Aerospace & Defense • Location: JBPHH, Hawaii, United States of America

Source: SAM.gov

Tender
Sources Sought

This is a Sources Sought Synopsis, not a solicitation for proposals. No contract will be awarded from this announcement. The 735th Air Mobility Squadron (AMS) is seeking to identify qualified and experienced businesses capable of performing the work described herein. The purpose of this RFI is to conduct market research to determine the availability and adequacy of potential business sources prior

Status
Prospective
Sector
Aerospace & Defense, Government, Seaport, Commercial, Residential, Manufacturing (Industrial)
Location
JBPHH, Hawaii, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about 735 Ams Hvac

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “735 Ams Hvac” is a tender record in Taiyo, linked to the Aerospace & Defense sector. It is issued for works, goods, or services related to JBPHH, Hawaii, United States of America.

Participants

Not available for this record.

Status

Original status

sources sought

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

This is a Sources Sought Synopsis, not a solicitation for proposals. No contract will be awarded from this announcement. The 735th Air Mobility Squadron (AMS) is seeking to identify qualified and experienced businesses capable of performing the work described herein. The purpose of this RFI is to conduct market research to determine the availability and adequacy of potential business sources prior to issuing a formal solicitation. The Government is seeking information from businesses that can provide all labor, tools, equipment, and supervision necessary to remove and replace twenty-six (26) Variable Air Volume (VAV) controllers and twenty-six (26) associated thermostats at Building 4069, Joint Base Pearl Harbor-Hickam, HI. Background & Scope of Work As detailed in the Performance Work Statement (PWS), the project requires the removal of 26 broken VAV controllers and 26 thermostats and the installation of new, customer-provided Carrier components. The scope includes, but is not limited to: De-energizing, disconnecting, and safely removing all specified broken/obsolete components. Installing 26 new VAV controllers and 26 new thermostats compatible with the existing building automation system. Performing all ancillary tasks required for a complete installation, including removing/replacing ceiling tiles, pulling new control wiring, and restoring the work site to its original condition. Properly removing and disposing of all old components and debris from the facility. Coordinating all work with the government Contracting Officer's Representative (COR). Required Contractor Qualifications & Certifications The Government has a strong preference for contractors who can demonstrate the following qualifications to ensure system integrity, warranty protection, and adherence to federal law. Respondents should clearly state their ability to meet the following criteria: Licensing: Possess a current HVAC contractor license. Any electrical work must be performed by a licensed electrician in accordance with the PWS. EPA Certification: All technicians performing work must hold an EPA Section 608 Certification for proper refrigerant handling, as required by the Clean Air Act. Manufacturer Authorization & Expertise (Highly Preferred): To protect the government's equipment warranty and ensure the highest quality of service, strong preference will be given to contractors who are Official Carrier Factory Authorized Dealers. Technician Certification (Highly Preferred): In lieu of or in addition to factory authorization, contractors whose technicians hold North American Technician Excellence (NATE) certification are also preferred. Use of Genuine Parts: The contractor will be required to use genuine, Original Equipment Manufacturer (OEM) parts for any components beyond the government-furnished controllers and thermostats to maintain system warranty. Requested Information for Interested Parties Interested parties are requested to submit a capabilities statement that addresses the following: Company Information: Company name, address, point of contact, phone number, email address, CAGE code, and Unique Entity ID (UEI). Business Size: Business size and status under NAICS code 238220 (e.g., Small Business, 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, etc.). Statement of Capability: A brief narrative detailing your company's experience with similar HVAC control system replacement projects, particularly for Department of Defense or other federal agencies. Qualifications and Certifications: Explicitly confirm your company’s ability to meet the mandatory and preferred qualifications listed in Section 2.0. Please state if you are a Carrier Factory Authorized Dealer and/or if your technicians hold NATE certifications. This RFI is for market research and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled as such. The Government will not pay for any information or administrative costs incurred in response to this RFI.

Original sector

Construction

Location

Country

United States of America (USA)

State

Hawaii

City

JBPHH

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Aerospace & Defense, Government, Seaport, Commercial, Residential, Manufacturing (Industrial)

Article published date

2026-07-01

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender