logo

Amendment To Solicitation For Ultra-High Vacuum Sample Backout Chamber

One of 10,000+ tenders Taiyo tracks in Colorado.

Source: SAM.gov

Tender
Combined Synopsis/Solicitation

AMENDMENT TO SOLICITATION FOR VENDOR QUESTIONS Solicitation 1333ND26QNB030068 Ultra High Vacuum Sample Backout Chamber Vendor Question 1: To accurately provide a quote for the chamber and frame, I would need a drawing, STEP file, and/or sketch, as a written description alone is not sufficient for an accurate quote. NIST Response: There are many ways to design and assemble a system with the capabil

Status
Closed
Sector
Water Supply and Storage, Seaport, Manufacturing (Industrial), Commercial, Residential
Location
Boulder, Colorado, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Amendment To Solicitation For Ultra-High Vacuum Sample Backout Chamber

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Amendment To Solicitation For Ultra-High Vacuum Sample Backout Chamber” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to Boulder, Colorado, United States of America.

Participants

Not available for this record.

Status

Original status

combined synopsis/solicitation

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

AMENDMENT TO SOLICITATION FOR VENDOR QUESTIONS Solicitation 1333ND26QNB030068 Ultra High Vacuum Sample Backout Chamber Vendor Question 1: To accurately provide a quote for the chamber and frame, I would need a drawing, STEP file, and/or sketch, as a written description alone is not sufficient for an accurate quote. NIST Response: There are many ways to design and assemble a system with the capabilities that we are requesting. We have not provided a technical drawing to allow the vendor the flexibility to design a system to meet our specifications as they see fit. We will evaluate on conformance to specifications, not a particular design. Vendor Question 2: Regarding Technical Specification b. “Partial pressure for masses >44 AMU: <5e-11 Torr”: How is this intended to be controlled / measured with a base pressure of 1e-8 Torr. NIST Response: We will verify the stated specification with an RGA unit in our lab. Ultimately, this specification is to ensure that the UHV system is not contaminated with higher amu contaminants. The overall pressure is allowed to be 1e-8 Torr due to lower amu components (e.g. water) that we can more readily get rid of with a bake-out. We are not equipped to do the requisite UHV cleaning for higher mass contaminants (silicones, oils, etc.) so this requirement ensures the vendor provides us with a UHV-clean system. Vendor Question 3: Will a cylindrical chamber work rather than a cube or a sphere, so long as the volume requirements are met and there are enough ports? NIST Response: A cylindrical chamber with the same 12” opening dimensions would also suffice. Vendor Question 4: What is the geometry of the sample types to be going into the chamber? Is it like a wafer? NIST Response: We will be using this chamber on a variety of sample sizes and shapes. As defined in the attached Combined Synopsis Solicitation, Statement of Work and applicable Clauses and Provisions.

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Colorado

City

Boulder

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Seaport, Manufacturing (Industrial), Commercial, Residential

Article published date

2026-02-19

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender