Contractor must test all burner safety and limit switches to include , but not be limited to : • Low and high gas pressure • Low water • Low low water ( Low water cut out ) • High pressure / temperature switches • Fuel valve proof of closure • Flame scanners • Air flow switches • Any other burner system rel

Status
Closed
Sector
Water Supply and Storage
Location
Wisconsin, United States of America
Updated
3 Nov 2026
Source
Wisconsin Purchasing Group

ConstructChat

Ask ConstructChat about Annual Boiler Testing & Tune - Up Services

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Annual Boiler Testing & Tune - Up Services” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to Wisconsin, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Contractor must test all burner safety and limit switches to include , but not be limited to : • Low and high gas pressure • Low water • Low low water ( Low water cut out ) • High pressure / temperature switches • Fuel valve proof of closure • Flame scanners • Air flow switches • Any other burner system related safety device • Bubble or leak test all fuel safety shut off valves and provide documentation stating whether the fuel safety valves give 100 % shut - off . 3 . 2 . 3 Contractor shall make necessary adjustments to the switches for proper trip points . 3 . 2 . 4 Contractor shall check all system linkages , ball joints , and assemblies for wear . 3 . 2 . 5 Contractor shall inspect all boilers / burners / systems and make recommendations for repairs and efficiency up - grades as necessary . 3 . 2 . 6 All inspections shall be external utilizing existing boiler site glasses for internal inspections .

Location

Country

United States of America (USA)

State

Wisconsin

Source

Source

Wisconsin Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage

Article published date

2026-05-06

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender