Assistance System for Surgical Procedure 1 Set
One of 10,000+ tenders Taiyo tracks in Japan.
Source: Japan External Trade Organization (JETRO)
Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : Assistance System for Surgical Procedure Set Type of the procurement : Purchase Basi requirements of the procurement : 4K Endoscopi Surgical System A A The camera console and camera head shall support 4K resolution and be capable of clearly visualizing fine anatomical structures within the
- Status
- Prospective
- Sector
- Power Generation (CCGT), Education, Commercial, Hospital, Residential
- Location
- Japan
- Updated
- 3 Nov 2026
- Source
- Japan External Trade Organization (JETRO)
ConstructChat
Ask ConstructChat about Assistance System for Surgical Procedure 1 Set
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | prospective |
Taiyo status | Prospective |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : Assistance System for Surgical Procedure Set Type of the procurement : Purchase Basi requirements of the procurement : 4K Endoscopi Surgical System A A The camera console and camera head shall support 4K resolution and be capable of clearly visualizing fine anatomical structures within the surgical field. B The system shall be equipped with four fluorescence imaging modes, including "SPY Overlay," to support blood flow assessment and tissue identification, enabling real-time diagnosis. C In addition to red, blue, and green LEDs, the system shall be capable of emitting lasers at specifi wavelengths (80 nm/83 nm), and the light source cable shall be compatible with high-pressure steam sterilization. D The system shall adopt an OLED display and have a Picture-in-Picture (PIP) function capable of displaying two images simultaneously. It shall also be equipped with a recording device capable of dual-channel simultaneous recording. E The system shall include an insufflation device that integrates heating, humidification, and smoke evacuation functions within a single unit, and the equipment cart shall be equipped with a switch that centrally controls the power supply of stored devices. 4K Endoscopi Surgical System B A The system shall support 4K resolution and be capable of acquiring and displaying extremely clear images of fine blood vessels, nerves, and tissue structures. B The system shall have a design and functionality that allow safe and smooth use in both endoscopi sinus surgery (ESS) and transcanal endoscopi ear surgery (TEES). C The system shall use an LED light source, providing long life and stable illumination, and shall enhance lesion visibility through fluorescence imaging and narrow band imaging using specialized light. D The system shall be equipped with high-definition video output interfaces such as HDMI, DVI, and/or SDI to ensure compatibility with medical imaging equipment and support high-quality video transmission and recording. Surgical Light A The system shall be equipped with a 4K high-resolution camera located at the center of the light head or at an optimal offset position, capable of capturing clear surgical field images. B The system shall provide high color rendering accuracy to faithfully reproduce tissue colors, minimize intraoperative shadows, and ensure sufficient illumination that reaches dee areas of the surgical field. C The system shall allow intuitive operation from both sterile and non-sterile areas, support saving settings according to surgical procedures and surgeon preferences, and enable synchronized control of multiple light heads. D The system shall be a ceiling-suspended type installable in existing operating rooms, featuring an easy-to-clean design and long-life LED light sources. Operating Table A The system shall allow a wide range of height adjustment from a minimum height of 52 mm or less to a maximum height of 1,00 mm or more, accommodating surgeon posture and surgical procedures. B The system shall have a wide range of motion, including Trendelenburg (pelvi elevation of 40°or more/reverse Trendelenburg of 30°or more) and lateral tilt (35°or more on both sides), enabling safe patient positioning. C The system shall provide a longitudinal slide range of 66 mm or more in the head-to-foot direction, allowing optimal imaging range when using fluoroscopi devices such as a C-arm. D The system shall be designed to reduce patient burden and maintain stability and safety even during prolonged fixation. Time limit for the submission of the requested material : 1 : 0 August, 202 Contact point for the notice : Hiroaki Kawamura, Procurement Services Office, Finance Department, Tohoku University, 2-1- Katahira Aoba-ku Sendai-shi 980-857 Japan, TEL 022-217-4869 |
Location
Country | Japan |
Source
Source | Japan External Trade Organization (JETRO) |
URL |
More Details
Record type | Tender |
Sector | Power Generation (CCGT), Education, Commercial, Hospital, Residential |
Article published date | 2026-06-16 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Power Generation (CCGT) tenders in Japan
- Ms Power Platform Mastering And Advanced Training (In Japanese & English) For Srf-Jrmc, Japan
- Swage Kit Assembly
- Modify Valve Test Stand X31I For Srf-Jrmc Yokosuka
- Commercial Power For The Life Support Area At Kyogamisaki Communication Site In Kyoto, Japan
- Fy27 Improve Family Housing Yokota Ab Paip 10 Phase 1 (32 Un)
- Telecommunications equipment
- Operation And Maintenance (O&M) Of Defense Information Systems Network (Disn) Power Plants And Station Battery Systems
- Control System Upgrades And Replacement Work On Tadano Infrastructure Solutions Co., Ltd. Land Portal Cranes, Lc47 And Lc48 At Berth 12 In The Commander Fleet Activities Yokosuka (Cfay), Japan
