logo

Assistance System for Surgical Procedure 1 Set

One of 10,000+ tenders Taiyo tracks in Japan.

Source: Japan External Trade Organization (JETRO)

Tender
Prospective

Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : Assistance System for Surgical Procedure Set Type of the procurement : Purchase Basi requirements of the procurement : 4K Endoscopi Surgical System A A The camera console and camera head shall support 4K resolution and be capable of clearly visualizing fine anatomical structures within the

Status
Prospective
Sector
Power Generation (CCGT), Education, Commercial, Hospital, Residential
Location
Japan
Updated
3 Nov 2026
Source
Japan External Trade Organization (JETRO)

ConstructChat

Ask ConstructChat about Assistance System for Surgical Procedure 1 Set

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Assistance System for Surgical Procedure 1 Set” is a tender record in Taiyo, linked to the Power Generation (CCGT) sector. It is issued for works, goods, or services related to Japan.

Participants

Not available for this record.

Status

Original status

prospective

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : Assistance System for Surgical Procedure Set Type of the procurement : Purchase Basi requirements of the procurement : 4K Endoscopi Surgical System A A The camera console and camera head shall support 4K resolution and be capable of clearly visualizing fine anatomical structures within the surgical field. B The system shall be equipped with four fluorescence imaging modes, including "SPY Overlay," to support blood flow assessment and tissue identification, enabling real-time diagnosis. C In addition to red, blue, and green LEDs, the system shall be capable of emitting lasers at specifi wavelengths (80 nm/83 nm), and the light source cable shall be compatible with high-pressure steam sterilization. D The system shall adopt an OLED display and have a Picture-in-Picture (PIP) function capable of displaying two images simultaneously. It shall also be equipped with a recording device capable of dual-channel simultaneous recording. E The system shall include an insufflation device that integrates heating, humidification, and smoke evacuation functions within a single unit, and the equipment cart shall be equipped with a switch that centrally controls the power supply of stored devices. 4K Endoscopi Surgical System B A The system shall support 4K resolution and be capable of acquiring and displaying extremely clear images of fine blood vessels, nerves, and tissue structures. B The system shall have a design and functionality that allow safe and smooth use in both endoscopi sinus surgery (ESS) and transcanal endoscopi ear surgery (TEES). C The system shall use an LED light source, providing long life and stable illumination, and shall enhance lesion visibility through fluorescence imaging and narrow band imaging using specialized light. D The system shall be equipped with high-definition video output interfaces such as HDMI, DVI, and/or SDI to ensure compatibility with medical imaging equipment and support high-quality video transmission and recording. Surgical Light A The system shall be equipped with a 4K high-resolution camera located at the center of the light head or at an optimal offset position, capable of capturing clear surgical field images. B The system shall provide high color rendering accuracy to faithfully reproduce tissue colors, minimize intraoperative shadows, and ensure sufficient illumination that reaches dee areas of the surgical field. C The system shall allow intuitive operation from both sterile and non-sterile areas, support saving settings according to surgical procedures and surgeon preferences, and enable synchronized control of multiple light heads. D The system shall be a ceiling-suspended type installable in existing operating rooms, featuring an easy-to-clean design and long-life LED light sources. Operating Table A The system shall allow a wide range of height adjustment from a minimum height of 52 mm or less to a maximum height of 1,00 mm or more, accommodating surgeon posture and surgical procedures. B The system shall have a wide range of motion, including Trendelenburg (pelvi elevation of 40°or more/reverse Trendelenburg of 30°or more) and lateral tilt (35°or more on both sides), enabling safe patient positioning. C The system shall provide a longitudinal slide range of 66 mm or more in the head-to-foot direction, allowing optimal imaging range when using fluoroscopi devices such as a C-arm. D The system shall be designed to reduce patient burden and maintain stability and safety even during prolonged fixation. Time limit for the submission of the requested material : 1 : 0 August, 202 Contact point for the notice : Hiroaki Kawamura, Procurement Services Office, Finance Department, Tohoku University, 2-1- Katahira Aoba-ku Sendai-shi 980-857 Japan, TEL 022-217-4869

Location

Country

Japan

Source

Source

Japan External Trade Organization (JETRO)

URL

More Details

Record type

Tender

Sector

Power Generation (CCGT), Education, Commercial, Hospital, Residential

Article published date

2026-06-16

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender