logo

Backflow Preventers

Sector: Aerospace & Defense • Location: Yuma, Arizona, United States of America

Source: SAM.gov

Tender
Sources Sought

The Regional Contracting Office MCI-West is conducting market research to identify contractors for providing Backflow Preventors to support Installation Marine Corps Air Station, Yuma, for a one-time buy of supplies. Please provide your total pricing for all items and quantities, to include unit prices, for budget estimates. The North American Industry Classification Standard (NAICS) code for this

Status
Prospective
Sector
Aerospace & Defense, Government, Residential, Commercial, Manufacturing (Industrial)
Location
Yuma, Arizona, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Backflow Preventers

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Backflow Preventers” is a tender record in Taiyo, linked to the Aerospace & Defense sector. It is issued for works, goods, or services related to Yuma, Arizona, United States of America.

Participants

Not available for this record.

Status

Original status

sources sought

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The Regional Contracting Office MCI-West is conducting market research to identify contractors for providing Backflow Preventors to support Installation Marine Corps Air Station, Yuma, for a one-time buy of supplies. Please provide your total pricing for all items and quantities, to include unit prices, for budget estimates. The North American Industry Classification Standard (NAICS) code for this project is 332911 (Industrial Valve Manufacturing with a size standard of 750 Employees, NAICS code compliance verification will occur if/when proposals are submitted). Minimum Salient Characteristics: See attached draft Minimum Salient Characteristics and respective specification PDFs. Responses to Request for Information: Contractors are reminded that this is a REQUEST FOR INFORMATION and is NOT a request for proposal/bid/quote. Responses to this notice shall not constitute responses to solicitation. Responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. This Request for Information is not to be construed as a commitment by the Government, nor will the Government pay for the information submitted in response. Respondents will not be notified of the results of any government assessments. It is requested that interested businesses submit to the contracting office a brief capabilities statement. The capabilities statement must clearly detail the firm's ability to perform all aspects of this notice and must include the following: a) Data Universal Numbering System (DUNS) number, Commercial and Government Entity (CAGE) code, and a statement regarding the socio-economic status of the company (Section 8(a) of the Small Business Act (8a) small business concern, certified Historically Underutilized Business Zone (HUBZone), Service-Disabled Veteran-Owned Small Business (SDVOSB) concern, etc.). b) Confirmation that your company can meet the certifications required in the Minimum Salient Characteristics, Proposed Units and Terms, and specification worksheet PDFs. c) Relevant Experience providing supplies identified in the DRAFT Minimum Salient Characteristics to include: experience in performing efforts of similar size and scope within the last three years. Please include a brief description of the project, contract number, and contract value. Proposals are not to be submitted at this time. This is a Request for Information only, NOT A REQUEST FOR PROPOSAL/BID/QUOTE. No questions will be answered. The information received will be utilized to assist in formulating the acquisition. Respondents will not be notified of the results of any government assessments. All responses will be treated as proprietary. THE DEADLINE FOR RECEIPT OF SUBMISSIONS IS 9 September 2026, 16:30PM (PDT). All submissions must be sent via electronic mail to: sabastian.dorsett@usmc.mil and allen.l.hayes@usmc.mil. Primary Point of Contact: Sgt Lake, Contract Specialist Regional Contracting Office MCI-WEST, Camp Pendleton, CA Email: sabastian.dorsett@usmc.mil Proposed Units and Terms: SIZE TYPE SPECS QUANITY DIMENSIONS FACT SHEET 1/2" 375XLRP WILKINS Size 20mm; Dimensions 8-7/8" 225mm 2 A 3/4" 375XLRP WILKINS Size 20mm; Dimensions 8-7/8" 225mm 4 A 1" 375XLRP WILKINS Size 25mm; Dimensions 11-3/16" 284mm 4 A 1" RPLF4A APOLLO Size 1"; 14-5/8 2 B 1" 975XLRP WILKINS Size 25mm; Dimensions 13" 330mm 2 C 1-1/2" 375XLRP WILKINS Size 40mm; Dimensions 15-1/4", 387mm 2 A 1-1/2" 975XLRP WILKINS Size 40mm; Dimensions 17-3/8", 441mm 2 C 2" 375XLRP WILKINS Size 50mm; Dimensions 16", 406mm 9 A 2" 825YRP FEBCO Size 17-3/4" 2 D 2" 765PVB FEBCO Size 50mm 5 E 2" 975XLRP WILKINS Size 50mm; Dimensions 18-1/2" 470mm 1 C 2-1/2" 009RP WATTS Size 65mm; Dimensions 41-1/4" 1048mm 2 Series 009RP WATTS PDF 3" 009RP WATTS Size 34 1/4" 870mm;Dimension 18.5" 470mm 5 Series 009RP WATTS PDF 4" 909RP WATTS Size 100mm;Dimensions 551/8" 1400mm 3 F 4" 957RP WATTS Size 857mm 33 3/4";Dimension 30 1/8" 765 mm 5 Series 957RP WATTS PDF 4" 375ARP WILKINS OSY Gate Size 100mm; Dimensions 37-5/8" 956mm 5 G 4" 709DC WATTS Dimensions. 52-3/8" 1332mm 2 I 6" 375XLRP WILKINS OSY Gate Size 150 Dimensions 44-3/4" 1137mm 2 J Attached are the Excel and Adobe documents providing further information on this requirement. The items can be any brand that meets the minimum specifications provided. Questions to be considered regarding this requirement: Approved Equals: Will the Government consider equivalent backflow prevention devices from other nationally recognized manufacturers when the specified manufacturer or model is unavailable, provided the proposed device meets or exceeds the required specifications and applicable certifications? Answer: Yes. Partial Deliveries: Will the Government permit partial or staggered deliveries when some devices are immediately available while others have longer manufacturer lead times? Answer: Yes. Multiple Manufacturers: Can a vendor provide devices from multiple approved manufacturers to satisfy the requirement, or must all devices be supplied by the same manufacturer? Answer: Yes. Substitutions Due to Availability: If a listed model is discontinued, backordered, or unavailable within the required delivery period, what documentation will be required for the Government to approve an equivalent substitute? Answer: A list of the specifications on the equivalent substitute before moving forward. Delivery Location and Freight: Will the formal solicitation identify the exact delivery location, unloading requirements, delivery hours, and whether a loading dock or forklift will be available for larger assemblies? Answer: Yes. Required Certifications: Are there specific certifications or approvals required for each device, such as ASSE, USC-FCCCHR, NSF/ANSI, AWWA, or other applicable standards, beyond the manufacturer specifications provided? Answer: No. The Required Delivery Date is 60 days post award, or sooner. Please let me know if there are any questions regarding this market research. Please be aware this is not a request for quotes or proposals and is SOLELY for market research purposes.

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Arizona

City

Yuma

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Aerospace & Defense, Government, Residential, Commercial, Manufacturing (Industrial)

Article published date

2026-09-04

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender