C1Da--657A4-26-104, Conduct Life Safety Review 0002
One of 10,000+ tenders Taiyo tracks in Missouri.
Source: SAM.gov
The purpose of this modification (#2) is to clarify Evaluation factor 1 and answer a question. 1. PROFESSIONAL QUALIFICATIONS: Provide brief resumes of proposed team members who will specifically serve as the Project Manager(s), Designers of Record, and Quality Control Manager(s). In addition, provide resumes of other relevant team members or frequent subcontractors who will perform technical task
- Status
- Closed
- Sector
- Residential, Hospital, Commercial
- Location
- Poplar Bluff, Missouri, United States of America
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about C1Da--657A4-26-104, Conduct Life Safety Review 0002
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | presolicitation |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The purpose of this modification (#2) is to clarify Evaluation factor 1 and answer a question. 1. PROFESSIONAL QUALIFICATIONS: Provide brief resumes of proposed team members who will specifically serve as the Project Manager(s), Designers of Record, and Quality Control Manager(s). In addition, provide resumes of other relevant team members or frequent subcontractors who will perform technical tasks under this contract including, but not limited to: Architects, Engineers (Mechanical, Electrical, Plumbing, Fire Protection/Life Safety), Communications Designer, Interior Designers, Cost Estimators, Environmental Safety & Health, CAD Tech. The surveyor shall have a minimum of ten years experience in completing Life Safety Code (NFPA 101) surveys in healthcare facilities and be knowledgeable with the Statement of Conditions process. Include their record of working together. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline in the state of Missouri or in a state which Missouri has recognized their license. b. Each resume shall include a minimum of three (3) and a maximum of five (5) specific completed projects in the past five (5) years that best illustrate the individual team members experience relevant to this requirement scope. Resume shall state the role the specific individual played in the project. Question: Is it the expectation that the selected AE team for this project would be acting as the facilities liaison to the Joint Commission, preparing those documents and attending any Joint Commission review? What qualifications beyond this would the VA be looking for. A. No, it is not expected that the selected AE team for this project would be acting as the facilities liaison to the Joint Commission, preparing those documents, and attending any Joint Commission review. Please see revised Evaluation factor 1 above. END OF MODIFICATION |
Original sector | Professional, Scientific, and Technical Services |
Location
Country | United States of America (USA) |
State | Missouri |
City | Poplar Bluff |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Residential, Hospital, Commercial |
Article published date | 2025-12-10 |