C1Da--Ae Upgrade Nursing Unit Isolation Rooms & Airflows - 583-25-202

Sector: Water Supply and Storage • Location: Richard L. Roudebush VA Medical Center 1481 W. 10th Street Indianapolis, IN 46202-2803

Source: SAM.gov

Tender
Presolicitation

Description of Requirement: The VAMC, Indianapolis has a requirement to maintain air pressure differentials between some designated patient rooms and the adjoining corridors or spaces. This pressure differential can be either positive, that is, the interior of the patient room has greater air pressure than does the adjoining corridor or space, or negative, that is, the interior of the patient room

Status
Closed
Sector
Water Supply and Storage, Hospital, Road, Residential, Government, Commercial
Location
United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about C1Da--Ae Upgrade Nursing Unit Isolation Rooms & Airflows - 583-25-202

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “C1Da--Ae Upgrade Nursing Unit Isolation Rooms & Airflows - 583-25-202” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to Richard L. Roudebush VA Medical Center 1481 W. 10th Street Indianapolis, IN 46202-2803.

Participants

Not available for this record.

Status

Original status

presolicitation

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Description of Requirement: The VAMC, Indianapolis has a requirement to maintain air pressure differentials between some designated patient rooms and the adjoining corridors or spaces. This pressure differential can be either positive, that is, the interior of the patient room has greater air pressure than does the adjoining corridor or space, or negative, that is, the interior of the patient room has a lower air pressure than does the adjoining corridor or space. Currently, some patient rooms are designed to be both positive and negative, selectable by a keyed interface. This dual functionality is no longer permitted under VA regulations so in accordance with the following table, each room shall be designated as either negative or positive; the keyed interface shall be disabled and removed, and the room operating sequence shall only function as indicated in the following table. Any equipment no longer required by this change shall be removed and discarded. At the conclusion of the project there shall be 27 negative pressure only rooms and four positive pressure only rooms. The terms positive and negative pressures shall be defined as follows: A single negative pressure symbol (-) shall mean a minimum negative pressure difference of 0.01 Water Column (WC); a double negative designation (--) shall mean a minimum negative pressure differential of 0.02 WC. A single positive pressure symbol (+) shall mean a minimum positive pressure differential of 0.01 WC. A double positive pressure symbol (++) shall mean a minimum positive pressure differential of 0.02 WC. The A/E shall inspect and review all components of each room that can influence the pressure balance; identify all deficient components; determine how the rooms are operating in their current configuration; determine what changes are required to enable the rooms to operate in conformance with current VA requirements and industry standards under normal conditions, under epidemic conditions, and in compliance with all fire and smoke regulations and requirements. Compliance with all fire and smoke regulations shall include both normal and epidemic conditions. The use of the phrase epidemic mode is defined to mean an operating condition in which all negative pressure rooms maintain design pressure differences and air changes concurrently; AHUs meet the minimum outdoor air and filtration set points, and sequences accommodate extended door-open events. After the A/E presents a list of deficiencies and solutions to the VA; the A/E shall design, in conjunction with the VA, solutions for the identified components and system deficiencies. The A/E shall prepare plans and specifications to remediate all such deficiencies in components and systems and provide project assistance through the bidding and construction phases. The hospital has 31 total pressure designated rooms with four rooms being designated as positive and the remaining 27 are designated as negative pressure rooms. Selection Criteria: (1) Professional qualifications necessary for satisfactory performance of required services. (2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. (3) Capacity to accomplish the work in the required time. (4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. (5) Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. (6) Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. (7) The extent to which potential contractors identify and commit to the use of service-disabled veteranowned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors. SF 330 Submittal Instructions: All interested and capable firms are to submit an electronic SF330 package for review. Physical copies will not be accepted. The SF330s can be submitted to the below email address: luke.turner@va.gov The package must be received and in government control by the closing time/date of this announcement.

Original sector

Professional, Scientific, and Technical Services

Location

Country

United States of America (USA)

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Hospital, Road, Residential, Government, Commercial

Article published date

2025-12-20

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender