logo

Calibration and Certification of Equipment used for Vapor Recovery

The scope, dates and status of this tender. A free account opens every field.

Source: California Purchasing Group

Tender
Closed

The California Air Resources Board ( CARB ) is seeking a Contractor to conduct NIST traceable calibrations . CARB is required by law to certify vapor recovery systems or components installed in gasoline dispensing facilities ( gas stations ) and to conduct testing to verify vapor recovery systems or components com

Status
Closed
Sector
Seaport
Location
California, United States of America
Updated
3 Nov 2026
Source
California Purchasing Group

ConstructChat

Ask ConstructChat about Calibration and Certification of Equipment used for Vapor Recovery

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Calibration and Certification of Equipment used for Vapor Recovery” is a tender record in Taiyo, linked to the Seaport sector. It is issued for works, goods, or services related to California, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The California Air Resources Board ( CARB ) is seeking a Contractor to conduct NIST traceable calibrations . CARB is required by law to certify vapor recovery systems or components installed in gasoline dispensing facilities ( gas stations ) and to conduct testing to verify vapor recovery systems or components comply with applicable CARB test procedures . These test procedures require instruments used for testing to be calibrated annually or semiannually and include National Institute of Standards and Technology ( NIST ) traceable certifications to produce valid and accurate results . Contractor shall provide and be responsible for all labor and materials / equipment to perform the services detailed in this Agreement . A . EQUIPMENT Contractor shall perform the services outlined in this Agreement on the equipment at the frequency listed below . The State reserves the right to add equipment similar to the list specified in this Agreement and delete equipment that has become obsolete through a formal amendment . QTY MODEL NUMBER SERIAL NUMBER FREQUENCY 1 Ashcroft ATE - 100 / FM Base Unit 7357 Annual 1 Ashcroft ATE - 100 / FM Base Unit 9213 Annual 1 Ashcroft AQS - 1 / FM Module ; ± 25 in WC ( 0 . 06 % accuracy ) 38723 Annual 1 Ashcroft AQS - 1 / FM Module ; ± 25 in WC ( 0 . 06 % accuracy ) 24260 Annual 1 Ashcroft AQS - 1 / FM Module ; ± 0 . 25 in WC ( 0 . 07 % accuracy ) 24256 Twice Yearly 1 Ashcroft AQS - 1 / FM Module ; ± 0 . 25 in WC ( 0 . 07 % accuracy ) 29084 Twice Yearly 1 Ashcroft AQS - 1 / FM Module ; ± 1 . 0 in WC ( 0 . 06 % accuracy ) 28024 Twice Yearly 1 Ashcroft AQS - 1 / FM Module ; ± 7 . 5 in WC ( 0 . 06 % accuracy ) 28025 Twice Yearly 1 Heise HQS - 1 / FM Module ; ± 3 . 0 in WC ( 0 . 06 % accuracy ) 58307 Twice Yearly 1 Heise HQS - 1 / FM Module ; ± 3 . 0 in WC ( 0 . 06 % accuracy ) 58308 Twice Yearly 1 Ashcroft AQS - 2 / FM Module ; 0 - 1000 mmHg Absolute ( 0 . 025 % accuracy ) 36603 Twice Yearly B . RATES Contractor shall be compensated for all costs associated with the services at the rate specified in Exhibit B , Attachment 1 – Contractor ’ s Rate Sheet . C . LOCATION Services shall be performed at the Contractor ’ s facility , unless otherwise specified . D . REPAIR Repair services are not included in this Agreement . Authorization for parts will be on an individual basis through a separate purchase order . In the event that there is a major instrument malfunction , the Contractor shall contact the Contract Manager for instructions . E . CALIBRATION 1 . Contractor shall perform calibration services on the equipment at the frequency specified in the table above . 2 . CARB shall ship equipment to the Contractor for calibration service in accordance with the Shipment of Equipment section . 3 . Contractor shall ensure all instruments used to calibrate the equipment shall be certified and traceable to the National Institute of Standards and Technology ( NIST ). 4 . Contractor shall identify all calibrated equipment by placing inspection stickers on the equipment . Stickers shall show the date of calibration , and signature of service technician calibrating the equipment . F . PARTS REPLACEMENT Replacement parts are not included in this Agreement and will be authorized only on a piece by piece basis through a separate purchase order . In the event that there is a major instrument malfunction , the Contractor shall contact the Contract Manager for instructions .

Location

Country

United States of America (USA)

State

California

Source

Source

California Purchasing Group

URL

More Details

Record type

Tender

Sector

Seaport

Article published date

2026-05-10

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender