logo

CHILLER COMPRESSOR REPLACEMENT

Sector: Water Supply and Storage • Location: MITN, United States of America

Source: MITN Purchasing Group

Tender
Closed

The purpose of the Request For Proposals (“ RFP ”) is for Royal Oak Schools ( the “ School District ”) to obtain proposals from qualified contractors for Royal Oak Schools Northwood Elementary School Chiller Compressor Replacement ( the “ Work ”). SCOPE OF WORK All items listed in the documents with the following c

Status
Closed
Sector
Water Supply and Storage, Metal, Power Generation (CCGT), Steel, Manufacturing (Industrial), Commercial
Location
MITN, United States of America
Updated
3 Nov 2026
Source
MITN Purchasing Group

ConstructChat

Ask ConstructChat about CHILLER COMPRESSOR REPLACEMENT

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “CHILLER COMPRESSOR REPLACEMENT” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to MITN, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The purpose of the Request For Proposals (“ RFP ”) is for Royal Oak Schools ( the “ School District ”) to obtain proposals from qualified contractors for Royal Oak Schools Northwood Elementary School Chiller Compressor Replacement ( the “ Work ”). SCOPE OF WORK All items listed in the documents with the following clarifications : 1 . Remove and replace compressor 1 on circuit 1 2 . Recover refrigerant charge . 3 . Change filter dryers dehydration of this compressor and circuit . 4 . Provide an unit price quote for any additional refrigerant . This shall not be included in the base bid . 5 . All equipment to complete this work . 6 . Other manufacturers are acceptable that are compatible with the existing equipment . 7 . Bidder shall include in their bid an allowance of $ 5 , 000 for each building to be used at the discretion of the District . The allowance shall include only direct costs . All other costs , such as overhead , profit , bond , or other items shall be included in base bid . Tag Data - Air - Cooled Helical Rotary Water Chillers ( Qty : 1 ) Item Tag ( s ) Qty Description Model Number A1 C - 1301 1 140 - 500 Ton Air - Cooled Series R ( TM ) ( RTA RTAC1554U ** HU Product Data - Air - Cooled Helical Rotary Water Chillers Item : A1 Qty : 1 Tag ( s ): C - 1301 Air cooled Series R ( TM ) model RTAC Startup Included - Trane Service must start equipment for warranty to be honored 155 nominal tons 460v / 60 hz / 3 ph High efficiency configuration C / UL listing ASHRAE 90 . 1 all versions up to 2016 ASME Remote evap , standard 40 - 60F leaving 2 pass arrangement , 0 . 75 " insulation Fluid type = water Low ambient capability Aluminum slit fins Low noise fans Wye - delta closed transition starter Single point connection main line unit power - ancillary items require other power Circuit breaker ( s ) - HACR rated BACnet interface Remote leaving temp and current setpoint Alarm relay High Amp short circuit rating Factory installed flow switch - for use when evap fluid type = water 15A 115V convenience outlet ( 60 Hz ) Refrigerant isolation valves Factory installed sound attenuator Architectural louvered panels Elastomeric isolators ( Fld ) 2 - 5th Year Replacement Compressor Warranty 1st Year Labor Warranty Whole Unit Performance Data - Air - Cooled Helical Rotary Water Chillers Tags C - 1301 Refrigeration capacity ( tons ) 161 . 55 IPLV . IP ( EER ( Btu / W - h )) 14 . 802 Flow evap ( gpm ) 386 . 11 Entering fluid evap ( F ) 55 . 00 Leaving fluid evap ( F ) 45 . 00 Fluid pressure drop evap ( ft H2O ) 11 . 29 Evap fouling factor ( hr - sq ft - deg F / Btu ) 0 . 000100 Number of condenser fans ( Each ) 11 . 00 Ambient air temp ( F ) 95 . 00 RLA - condenser fan ( each ) ( A ) 2 . 70 Operating weight ( lb ) 12445 . 0 Shipping weight ( lb ) 12114 . 0 Width ( in ) 90 . 200 Length ( in ) 232 . 000 Height ( in ) 93 . 000 Single point power MOP ( A ) 400 . 00 Single point power MCA ( A ) 315 . 00 COP ( COP ( kW / kW )) 3 . 166 Short circuit current rating ( A ) 65000 . 00

Location

Country

United States of America (USA)

State

MITN

Source

Source

MITN Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Metal, Power Generation (CCGT), Steel, Manufacturing (Industrial), Commercial

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender