Chiller Replacement Roybal Campus
Sector: Water Supply and Storage • Location: Georgia, United States of America
Source: Georgia Purchasing Group
THIS IS A SOURCES SOUGHT NOTICE . THIS IS NOT A REQUEST FOR PROPOSALS , QUOTATIONS OR BIDS . THERE WILL NOT BE A SOLICITATION , SPECIFICATIONS , OR DRAWINGS AVAILABLE AT THIS TIME . The Centers for Disease Control and Prevention ( CDC ) will likely issue a solicitation , as a Request for Proposal ( RFP ), for des
- Status
- Closed
- Sector
- Water Supply and Storage, Warehouse, Government, Commercial, Residential
- Location
- Georgia, United States of America
- Updated
- 3 Nov 2026
- Source
- Georgia Purchasing Group
ConstructChat
Ask ConstructChat about Chiller Replacement Roybal Campus
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | THIS IS A SOURCES SOUGHT NOTICE . THIS IS NOT A REQUEST FOR PROPOSALS , QUOTATIONS OR BIDS . THERE WILL NOT BE A SOLICITATION , SPECIFICATIONS , OR DRAWINGS AVAILABLE AT THIS TIME . The Centers for Disease Control and Prevention ( CDC ) will likely issue a solicitation , as a Request for Proposal ( RFP ), for design build construction services for a central plant modernization and chiller replacement at the CDC Roybal campus located at 1600 Clifton Rd ., Atlanta , GA 30329 in calendar year 2026 . CDC requests letters of interest from qualified SMALL AND LARGE BUSINESS MECHANICAL CONTRACTORS THAT CAN PERFORM AS A PRIME GENERAL CONTRACTOR on the planned central plant modernization and chiller replacement in Atlanta , Georgia . By way of this Sources Sought , CDC intends to determine the extent of capable firms that are engaged in providing the construction services described hereunder . Responses to this notice are not offers and cannot be accepted by the U . S . Government to form a binding contract . It is the responsibility of the interested parties to monitor this site for additional information pertaining to this notice . Response to this Request for Information is not mandatory for consideration in any subsequent Request for Proposal . The Modernization will include design build mechanical work including replacement of four existing 1 , 450 ton chillers with 1 , 800 ton chillers , replacement of eight cooling towers and four chilled water pumps . Due to the 24 / 7 operation of the central plant and campus demands ; of the 4 chillers to be replaced only 2 can be taken out of operation and bypass piping will need to be installed to facilitate shutdown . Contracting performing work must have a 2 hour emergency response time . Electrical work includes installation of two new Motor Control Centers ( MCC ), replacing medium voltage ( MV ) starters and recircuiting . The project also involves , building automation systems ( BAS ), fire protection , architectural and structural work . As part of the design - build scope , the design portion includes providing complete for construction design documents and construction services , including , but not limited to : management and inspection services , bonds , insurance , CPM schedules , health and safety plan , quality control plan , product submittal development and review , develop required coordination drawings , construction administration services , security and logistic control , furnish tools , materials , equipment , labor and incidentals , safety review / inspections , quality control , coordinate all construction related work , test and inspections , commissioning , operational manuals , facilities maintenance training , record documents , warranties , and other related professional services . This procurement is anticipated to be unrestricted regarding business size . Interested contractors must have an active registration , including completion of the annual representations and certifications , in the System for Award Management ( SAM ) at http :// sam . gov at the time of proposal submission in order to be eligible for award . Only Contractor firms and their major consultants / joint venture partners having offices within the continental United States will be considered for this procurement . The proposed project is anticipated to be a competitive , firm - fixed - price , construction contract procured in accordance with FAR Part 15 , Contracting by Negotiation , under a Best Value - Tradeoff Process . The estimated magnitude of construction is over $ 10 million . The North American Industry Classification System ( NAICS ) for this requirement is 238220 ( Commercial and Intuitional Building Construction ) Business Size Standard of $ 45 Million . Submission Instructions : Narrative shall be no longer than 8 pages . Comments will be shared within the Government and the Integrated Project Team but will otherwise be held in strict confidence . Should you respond to this Request for Information , please submit the following information : 1 . Firm ’ s name , address , point of contact , phone number , and e - mail address , and capabilities . 2 . Firm ’ s level of interest in competing on the solicitation when it is issued . 3 . Firm ’ s Business Size – Large , Small , Small Disadvantaged Business ( SDB ), Service Disabled Veteran Owned Small Business ( SDVOSB ), Historically Underutilized Business Zones ( HubZone ), Woman Owned Small Business ( WOSB ), certified 8 ( a ) firms , and SBA approved Mentor - Protégé firms . 4 . Firm ’ s experience in successfully completed central plant renovation projects of similar size and dollar value range over $ 10 , 000 , 000 . 00 . 5 . Firm ’ s bonding level . THIS NOTICE IS NOT A REQUEST FOR PROPOSAL , QUOTE OR BID . It is one market research tool being utilized to determine the availability of potential qualified contractors in acquisition planning . In addition , this Request for Information is not to be considered as a commitment by the Government , nor will the Government pay for any information solicited or delivered . Response is not required for eligibility to participate in any subsequent Request for Proposal . Interested parties who consider themselves qualified to perform the above - listed requirement are invited to submit a response to this Request for Information no later than 5 : 00 P . M . Eastern Standard Time ( EST ) Feburary 18 , 2026 . All responses under this Sources Sought must be emailed to Simi Khera , hkhera @ cdc . gov referencing the SAM Publication number 75D301 - 26 - R - 73398Telephone inquiries will not be accepted or acknowledged , and no feedback or evaluations will be provided to companies regarding their submissions . If you have any questions concerning this opportunity , please contact : Simi Khera via email at hkhera @ cdc . gov . |
Location
Country | United States of America (USA) |
State | Georgia |
Source
Source | Georgia Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Warehouse, Government, Commercial, Residential |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Water Supply and Storage tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Sole Source for Wedeco UV BulbsBallets
- Security Hardware Services
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- UNPAINTED SNOW FENCE AND DUNE GRASS NO II
- PreQualification of Bidders for Chaboya Improvements