DC Power System with Inverter
Bids closed Apr 2026 · West Virginia · Last reported Apr 2026
Source: West Virginia Purchasing Group
The West Virginia Department of Homeland Security - Division of Administrative Services is soliciting bids on behalf of the West Virginia Emergency Management Division to establish an open - end contract for DC Power Systems with Inverters . The Contract awarded from this Solicitation shall cover all items from
- Status
- Closed
- Sector
- Energy Storage, Power Generation (CCGT), Manufacturing (Industrial)
- Location
- West Virginia, United States of America
- Updated
- 3 Nov 2026
- Source
- West Virginia Purchasing Group
ConstructChat
Ask ConstructChat about DC Power System with Inverter
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The West Virginia Department of Homeland Security - Division of Administrative Services is soliciting bids on behalf of the West Virginia Emergency Management Division to establish an open - end contract for DC Power Systems with Inverters . The Contract awarded from this Solicitation shall cover all items from the Vendor ’ s Catalog . The successful Vendor shall provide all catalog items to the Agency at discount . GENERAL REQUIREMENTS : 3 . 1 Contract Items and Mandatory Requirements : Vendor shall provide Agency with the Contract Items listed below on an open - end and continuing basis . Contract Items must meet or exceed the mandatory requirements as shown below . 3 . 1 . 1 All Contract Items must carry a 3 - year replacement warranty . 3 . 1 . 2 Must have full function post factory system testing and report prior to shipment . 3 . 1 . 3 Controllers must be pre - configured to Manufacturers ’ specifications with battery programming . 3 . 1 . 4 Vendor must manage and honor any and all warranty claims associated with this contract . 3 . 1 . 5 Must have advanced replacement during warranty period . 3 . 1 . 6 Eligible Items # 1 – DVT 500Amp 19 ” Power System 3 . 1 . 6 . 1 Fully Racked and Ready DVT 500A DC Backup Power System with six lithium batteries . 3 . 1 . 6 . 1 . 1 Must be - 48V . 3 . 1 . 6 . 1 . 2 Must support eight ( 8 ) quantity 60 Amp rectifiers . 3 . 1 . 6 . 1 . 3 Must include the availability of dual - feed jumpers . 3 . 1 . 6 . 1 . 4 Must be 10RU in size . 3 . 1 . 6 . 1 . 5 Must be 19 ” wide . 3 . 1 . 6 . 1 . 6 Must have negative voltage output . 3 . 1 . 6 . 1 . 7 Must have 21 load breaker positions 3 . 1 . 6 . 1 . 8 Must have three ( 3 ) bulk load positions 3 . 1 . 6 . 1 . 9 Must have bulk battery positions through a Shunt only . 3 . 1 . 6 . 1 . 10 Must include 19 secondary distribution positions . 3 . 1 . 6 . 1 . 11 Can not have any programing other than original manufacturers programing . 3 . 1 . 6 . 2 DVT Cover for 19 ” Power System 3 . 1 . 6 . 2 . 1 Must be able to cover top of system to avoid internal damage . 3 . 1 . 6 . 3 DVT 60Amp DC Rectifiers 3 . 1 . 6 . 3 . 1 Must allow 85 - 305VAC . 3 . 1 . 6 . 3 . 2 Must be fan cooled , front to back . 3 . 1 . 6 . 3 . 3 Must provide output of a minimum 3000W at 176 - 305VAC , 3000W at 176VAC Linearly to 1382W at 85VAC . 3 . 1 . 6 . 3 . 4 Must have efficiency of a minimum of 96 . 2 percent . 3 . 1 . 6 . 3 . 5 Must be able to operate from - 40 degrees Celsius to + 45 degrees Celsius . 3 . 1 . 6 . 3 . 6 Must be able to automatically shut down at 75 degrees Celsius , and automatically restart at lower temperature . 3 . 1 . 6 . 4 DVT Rectifier Slot Filler 3 . 1 . 6 . 4 . 1 Must be black in color for uniformity . 3 . 1 . 6 . 4 . 2 Must be 4 . 25 x 1 . 69 inches in size . 3 . 1 . 6 . 5 DVT 19 ” Modular , Rack - Mount 48VDC120VAC Inverter 3 . 1 . 6 . 5 . 1 Must offer 2 . 5 kVA power per module . 3 . 1 . 6 . 5 . 2 Must allow for DC Input : 48VDC ( 32 - 63V ), 110VDC ( 90 - 160V ), 220 VDC ( 170 - 300V ). 3 . 1 . 6 . 5 . 3 Must allow for AC Output : 120VAC or 230VAC ( selectable ). 3 . 1 . 6 . 5 . 4 Must have a minimum efficiency of 96 % ( AC / AC ), 93 . 7 % ( DC / AC ). 3 . 1 . 6 . 5 . 5 Must have ability to house three ( 3 ) inverter modules . 3 . 1 . 6 . 6 DVT 2 . 5 kVA Inverter Modules 3 . 1 . 6 . 6 . 1 Must utilize three ( 3 ) modules for maximum power . 3 . 1 . 6 . 6 . 2 Must have output power of 2 . 5kVA / 2kW . 3 . 1 . 6 . 6 . 3 Must offer DC / AC Efficiency of a minimum of 91 %. 3 . 1 . 6 . 6 . 4 Must offer AC / AC Efficiency of a minimum of 95 %. 3 . 1 . 6 . 7 DVT60AE Breakers 3 . 1 . 6 . 7 . 1 Must be 16 ( quantity ) load breakers . 3 . 1 . 6 . 7 . 2 Must be 60Amp Electro - Mechanical Bullet Breakers . 3 . 1 . 6 . 8 DVT30AE Breakers 3 . 1 . 6 . 8 . 1 Must be 14 ( quantity ) load breakers 3 . 1 . 6 . 8 . 2 Must be 30Amp Electro - Mechanical Bullet Breakers . 3 . 1 . 6 . 9 DVT 19 ” Seismic Relay Rack 3 . 1 . 6 . 9 . 1 Must be 2 - post 19 ” wide 7ft . tall relay rack . 3 . 1 . 6 . 9 . 2 Must be seismic rated zone 4 , up to 2500lb . 3 . 1 . 6 . 9 . 3 Must have a minimum of 3000lb . static load capacity . 3 . 1 . 6 . 10 DVT25624 Distribution Panel 3 . 1 . 6 . 10 . 1 Must offer 10 / 10 GMT positions . 3 . 1 . 6 . 10 . 2 Must have a 600Amp Bus . 3 . 1 . 6 . 10 . 3 Must allow the use of TLS , TPC , and TPS Fuses , as well as Single Pole Breakers . |
Location
Country | United States of America (USA) |
State | West Virginia |
Source
Source | West Virginia Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Energy Storage, Power Generation (CCGT), Manufacturing (Industrial) |
Article published date | 2026-05-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Energy Storage tenders in United States of America
- HOUSEHOLD SINGLEUSE RECHARGEABLE BATTERY COLLECTION AND RECYCLING SERVICES
- BATTERIES FOR SURVEILLANCE EQUIPMENT
- Southeast Water Pollution Control Plant Power Feed and Prima...
- Flashlights and Batteries
- IFB 970302022LW Flashlights and Accessories
- Power Utility Rate Consulting Services for 2021 Electric Rates Study
- RFP - Portable Mass Spectrometer Device
- Southeast Water Pollution Control Plant Power Feed and Prima...
