The purpose of this Request for Proposal is to seek the service of qualified professional fire alarm system designers / installers to replace an existing fire alarm system at the district . The proposal is to include the design , supply and installation of a new system to meet current Fire Alarm codes .
- Status
- Closed
- Sector
- Commercial
- Location
- MITN, United States of America
- Updated
- 3 Nov 2026
- Source
- MITN Purchasing Group
ConstructChat
Ask ConstructChat about Design Build Fire Alarm Replacement
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The purpose of this Request for Proposal is to seek the service of qualified professional fire alarm system designers / installers to replace an existing fire alarm system at the district . The proposal is to include the design , supply and installation of a new system to meet current Fire Alarm codes . Scope of Services The scope of work must include but is not limited to the removal of existing fire alarm system , design of a new fire alarm system and the installation of that system . Work to include but not limited to : • Design and CAD plan documentation of a new Fire Alarm system following the Michigan Fire Prevention Code , PA207 , along with the State Fire Safety Board fire safety rules . • All permits and fees associated with the project ( this cost will be a direct reimbursement from the district . No mark up allowed ). • Submittal to the State of Michigan Bureau of Fire Services for plan review and all responses to state reviews to complete the project . • Removal of existing equipment and devices as required . The existing system must remain operational until the new system is functional . • Supply and installation of a new fire alarm system to include devices and wiring . All conduit to be run in ceilings and walls whenever possible for the new installation . All visual conduits shall be placed in wire mold with a color agreed upon by the district . • Any other items required for a complete Fire Alarm replacement ( not limited to but to include new mechanical smoke detectors if required ). • All final reviews and documentation required by the State of Michigan for building occupancy . • Training for district employees on the operation of the fire alarm system . • Contractors will be responsible for any and all damage to existing finishes due to construction . Any damage caused by the contractor must be repaired within ten ( 10 ) working days at the expense of the contractor . If damage occurs , the contractor will be liable for such damages . |
Location
Country | United States of America (USA) |
State | MITN |
Source
Source | MITN Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Commercial |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Commercial tenders in United States of America
- Sanitary Sewer Lateral Lining Pilot Program Section 230067500SA
- Trophies Plaques Awards ETC
- Painting Services for Building Exteriors Infrastructure Systems and Pressure Washing
- OAM Learning Management System
- CYBER SECURITY PENETRATION TESTING
- PROMOTIONAL ITEMS SOUVENIRS
- Proposed Services at Former Ingleside Recreation Center
- Towing Services CityOwned Vehicles Light and Heavy Duty