Ductless Mini - Split Installations Belknap County
Sector: Road • Location: New Hampshire, United States of America
Source: New Hampshire Purchasing Group
2 . Equipment to be Installed Conference Room System ( 2 ) Mitsubishi Hyper Heat Condensing Units Model : MXZ - 3C24NAHZ4 - U1 ( 4 ) Mitsubishi 2 ' x 2 ' 4 - Way Ceiling Cassette Units with Grilles Model : SLZ - AF12NL ( 1 ) 18 ” Fixed Stand for Condenser mounting Server Room System ( 1 ) Mitsubishi P - Series Condensing
- Status
- Closed
- Sector
- Road, Wind, Residential, Oil and Gas, Commercial
- Location
- New Hampshire, United States of America
- Updated
- 3 Nov 2026
- Source
- New Hampshire Purchasing Group
ConstructChat
Ask ConstructChat about Ductless Mini - Split Installations Belknap County
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 2 . Equipment to be Installed Conference Room System ( 2 ) Mitsubishi Hyper Heat Condensing Units Model : MXZ - 3C24NAHZ4 - U1 ( 4 ) Mitsubishi 2 ' x 2 ' 4 - Way Ceiling Cassette Units with Grilles Model : SLZ - AF12NL ( 1 ) 18 ” Fixed Stand for Condenser mounting Server Room System ( 1 ) Mitsubishi P - Series Condensing Unit ( Cooling Only ) Model : PUY - AH30NL ( 1 ) Mitsubishi Wall - Mounted Indoor Unit Model : PKA - AK30NL 3 . General Scope Requirements The Contractor shall : Verify all existing site conditions prior to bidding . SITE VISITATION MANDATORY . Furnish all materials , accessories , and appurtenances required for a complete installation . 4 . Mechanical Installation Requirements 4 . 1 Refrigeration Systems Install all refrigerant piping per manufacturer specifications . Pressure test , evacuate , and charge systems in accordance with industry standards . Provide line hide , insulation , and UV protection for all exterior piping . Ensure proper oil return and line sizing . Insulate all piping . 4 . 2 Indoor Units Install ceiling cassette units in Conference Room ceiling grid . Coordinate exact locations with Owner prior to installation . Provide condensate pumps ( if required ) and properly route all drain lines to approved discharge locations . Install wall - mounted unit in Server Room with proper clearances and access . 4 . 3 Outdoor Units Install condensers on furnished 18 ” stand or equivalent approved support system . Secure units to meet wind and snow load requirements applicable to New Hampshire . Maintain manufacturer - recommended clearances . Provide vibration isolation . 5 . Electrical Scope The Contractor shall provide all electrical work required for a complete and operational system , including : Circuit breakers sized per manufacturer requirements . Electrical disconnects within line of sight of each condenser . Low - voltage communication wiring between indoor and outdoor units . Control wiring and interconnections . Coordination with existing building electrical capacity . Labeling of all new circuits and equipment . 6 . Roof Penetrations and Weatherproofing Provide all required roof penetrations for refrigerant piping , electrical conduit , and condensate lines . All penetrations shall be : o Properly flashed and sealed o Installed in accordance with roofing manufacturer standards Contractor shall be responsible for maintaining roof integrity and preventing leaks . Any damage to the roof system shall be repaired at Contractor ’ s expense . |
Location
Country | United States of America (USA) |
State | New Hampshire |
Source
Source | New Hampshire Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Road, Wind, Residential, Oil and Gas, Commercial |
Article published date | 2026-04-28 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Road tenders in United States of America
- RFP - Pro-Tem Hearing Examiner
- NEW TIRES RETREADS AND TIRE SERVICES
- Professional Construction Engineering and Inspection CEI Services for the Williamson Boulevard Widening
- Lincoln Avenue Wascher to Killarney Preliminary Engineering Section 220065800PV
- KilleenFort Hood Regional Airport KFHRA Terminal Apron Rehabilitation Phase II
- IFB 947902022JM Screening 10 Asphalt Filter Stone 8 Granite Double Washed
- IFB 914202022AM Street Sweeper Parts and Brooms
- IFB 843402021AB Hay Alfalfa and Wheat Straw for Norfolk Zoo