logo
TenderClosed

Electrical & Mechanical Maintenance ServicesWater Treatment Plant & Wastewater Treatment Plant

Sector: Metal • Location: Tennessee, United States of America

Source: Tennessee Purchasing Group

THE PURPOSE OF THIS BID IS TO OBTAIN A CONTRACTOR TO PROVIDE MAINTENANCE SERVICES FOR THE TOWN ' S WATER AND WASTEWATER MECHANICAL EQUIPMENT AND ELECTRIC MOTORS . THE MOTOR REPAIR SHOP MUST MAINTAIN A VALID TENNESSEE MECHANICAL CONTRACTOR ’ S LICENSE . IF MOTOR REPAIR WORK IS NOT TO BE CONDUCTED IN HOUSE ,

Status
Closed
Sector
Metal, Water Supply and Storage, Manufacturing (Industrial), Commercial
Location
Tennessee, United States of America
Updated
3 Nov 2026
Source
Tennessee Purchasing Group

ConstructChat

Ask ConstructChat about Electrical & Mechanical Maintenance ServicesWater Treatment Plant & Wastewater Treatment Plant

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Electrical & Mechanical Maintenance ServicesWater Treatment Plant & Wastewater Treatment Plant” is a tender record in Taiyo, linked to the Metal sector. It is issued for works, goods, or services related to Tennessee, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

THE PURPOSE OF THIS BID IS TO OBTAIN A CONTRACTOR TO PROVIDE MAINTENANCE SERVICES FOR THE TOWN ' S WATER AND WASTEWATER MECHANICAL EQUIPMENT AND ELECTRIC MOTORS . THE MOTOR REPAIR SHOP MUST MAINTAIN A VALID TENNESSEE MECHANICAL CONTRACTOR ’ S LICENSE . IF MOTOR REPAIR WORK IS NOT TO BE CONDUCTED IN HOUSE , THE MOTOR REPAIR SHOP MUST BE APPROVED BY A REPRESENTATIVE OF THE TOWN OF SMYRNA . A PANEL OF INSPECTORS FROM THE TOWN MAY VISIT AND INSPECT THE FACILITIES BEFORE AWARD OF BID . ALL MOTOR REPAIR WORK MUST BE COMPLIANT WITH EASA STANDARDS AND SPECIFICATIONS , SUCH AS ANSI / EASA AR100 , TO ENSURE THE REPAIR PROCESS MAINTAINS THE EFFICIENCY AND RELIABILITY OF THE MOTOR , FOLLOWING BEST TRADE PRACTICES AND PROCEDURES . ELECTRIC MOTOR REWIND SPECIFICATION ( Motors only ) All electric motor stator rewinding shall include labor and partial material for the following scope of work : 1 . Dismantle , test , and strip coils 2 . Fabricate and install coils . 3 . Connect VPI valves 4 . Assemble , test , and paint . 5 . A 90 - day warranty against defects in materials and workmanship shall be provided by the Contractor . 6 . Dynamic balance , furnishing and installing bearings , metalizing , machine work , and new leads are additions to the scope . 1 . Before dismantling the motor , inspect the motor by turning the rotor to identify a sprung shaft , rubbing , bearing noise or roughness , excessive end play , or other problems , and record findings . Perform electrical tests on the motor and dismantle it for inspection and cleaning . Stators , wound rotors , and armatures to be rewound shall be burned and stripped at a maximum controlled temperature of 750 degrees F . to prevent damage to the lamination and frames . 2 . All motor windings will be steam cleaned using detergent and rinsed with clean steam . The motor will be baked dry in a temperature - controlled oven following standard shop procedures . After the first bake , allow motor windings to cool to normal temperature . Perform a megger test on the windings . The minimum acceptable reading is 100 megohms at 1000 volts DC of operating voltage . If reading is unacceptable , inspect motor windings for cleanliness . If windings are not clean ( i . e ., dirt , grease , detergent residue ), steam clean motor windings again . If windings are clean , bake them again in a temperature - controlled oven following standard shop procedures . After the second bake , allow motor windings to cool to normal temperature . Perform a megohmmeter test on the windings . If readings are unacceptable , then contact the Plant Manager for further instructions . If readings are acceptable , dip and bake motor windings . 3 . After stripping , examine and test laminations for blow holes , shorts , and hot spots . All short and / or laid - over laminations shall be repaired before rewinding . Sandblast and thoroughly clean slots and frames , check for cracks or broken welds , repair as necessary , and perform an iron core loss test . Check the rotor for cracks , flaws , bearing fit , and fan condition . Check air gaps for condition and correct distance . Determine bearing fit at bearing locations in the end bells and on the shaft . 4 . Check nameplate date and purchase order to determine the type and class of insulation of new coils . Class " N " insulation and the VPI process and epoxy resin are required . Fabricate and install coils to conform to OEM Factory standards and specifications or better . Every coil is to be tied on both sides of the winding and formed neatly and compactly . All insulating varnish shall have a heat aging life of not less than 10 , 000 hours at maximum operating temperature . Class " H ", epoxy insulation is standard . If in doubt , contact the Town of Smyrna for directions before continuing with the work . 5 . Silicone rubber - insulated Class " H " leads are standard . On 230 / 460 motors , leads shall be for the higher voltage and suitably sealed at the point of exit from the stator on TEFC and explosion - proof motors . 6 . The vacuum pressure impregnation ( VPI ) Epoxy Resin process is to be used , unless instructed otherwise . 7 . After varnishing and baking , check stator insulation resistance at twice the rated voltage or 500 DC Volts for motors under 440 volts and 1000 DC Volts on motors 440 Volts or greater . In general , a minimum value of 100 megohms resistance for 250 Volts AC and under , and 200 megohms for 251 to 600 Volts AC motors is required with the entire winding to ground , 1 minute duration , temperature 30 degrees C . 8 . Check the rotor between centers on a lathe for runout , which should not exceed 0 . 003 inches or 0 . 0005 inches after resurfacing . Check bearing mount areas for condition and fit using the bearing manufacturer ' s data for dimensions and tolerances . 9 . All NEMA frame A / C electric motor rotors 5 H . P . and larger are to be dynamically balanced . For motors 50 H . P . and larger balanced to the " GOOD " range , according to the Vibration Frequency Curve , the spectrum analysis method is required , and copies of the vibration spectrum plots from the test stand runs are to be furnished to the Town . The spectra should be taken in the horizontal , vertical , and axial directions on both bearings . On ball bearing motors , the range should be from 2 mils to 4 mils . If there are questions regarding these requirements , consult the Town before proceeding . 10 . Use loose - fit Bearing Fit Tolerance Chart bearings on all 3600 RPM motors . Check for a tight fit between bearing and bearing housing , which should be 0 . 001 inches of interference , up to 0 . 0005 inches per bearing outside diameter , for a secure fit . Use identical replacement bearings , unless otherwise specified . 11 . On all motors , use OEM - recommended grease , unless otherwise specified , and plainly identify on the motor as to the type of grease used . 12 . A non - hardening sealant compound , RTV silicone , Permatex # 2 , or equal is to be used during assembly on all end bells , bearing caps , etc ., to prevent moisture and fumes from entering the motor on all TEFC or explosion - proof motors . Check the fan and covers , and repair or replace any defective components . 13 . All motors are to be repainted after rewinding or repairs . Use appropriate standard engineering specifications and applicable surface preparation . Use the standard machine gray color . 14 . Perform a megger test after assembly to ensure there was no damage to the motor during assembly . Allow the motor to run long enough to reach a normally stable temperature . Check bearings for noise and excessive temperature , and do a vibration profile and run test of the motor . See preceding requirements for spectrum analysis of vibration . Record no - load amperage for phase balance and comparison to the full load current rating of the motor . Record RPM , bearing temperatures , and coast down . Check and mark the magnetic center on the shaft for installation reference , if applicable .

Location

Country

United States of America (USA)

State

Tennessee

Source

Source

Tennessee Purchasing Group

URL

More Details

Record type

Tender

Sector

Metal, Water Supply and Storage, Manufacturing (Industrial), Commercial

Article published date

2026-05-05

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender