logo

ELISA Instrument - DFS - AO

Location: Illinois, United States of America

Source: Illinois Purchasing Group

Tender
Closed

The purchase of two Enzyme - Linked Immunosorbent Assay ( ELISA ) screening instruments . One instrument is for the Chicago Toxicology Lab and the other is for the Springfield Toxicology Lab . The ELISA screening method is an end - point heterogenous competitive enzyme immunoassay technique used for the analysis of

Status
Closed
Location
Illinois, United States of America
Updated
3 Nov 2026
Source
Illinois Purchasing Group

ConstructChat

Ask ConstructChat about ELISA Instrument - DFS - AO

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “ELISA Instrument - DFS - AO” is a tender record in Taiyo. It is issued for works, goods, or services related to Illinois, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The purchase of two Enzyme - Linked Immunosorbent Assay ( ELISA ) screening instruments . One instrument is for the Chicago Toxicology Lab and the other is for the Springfield Toxicology Lab . The ELISA screening method is an end - point heterogenous competitive enzyme immunoassay technique used for the analysis of specific compounds in biological materials . The Toxicology Section will use these instruments to conduct drug analysis on blood and urine in DUI , criminal sexual assault , and homicide cases . These instruments will be used to replace aging and worn ELISA instruments . Newer and advanced instrumentation will provide more robust and sensitive methods to improve analysis , increase efficiency , reduce downtime , and ensure quality . SUPPLIES AND / OR SERVICES REQUIRED : ELISA instrument must meet the following specs Must be a fully automated ELISA system that allows for multiple assays , a minimum of 4 , on a single plate . Automation of the system must allow for complete walk - away analysis of up to 384 samples ( as contained on four 96 - well microtitre plates ). Walk away analysis requires no operator intervention after initialization of sample analysis until analysis is complete . System must be based on conventional ELISA techniques where the operating principle is based on competitive binding between enzyme labeled drug and drug in samples , controls , and calibrators . Instrument must use conventional enzyme labeling and measurement of reaction via spectrophotometric techniques . The system must include all components and accessories necessary for analysis to include all fluid handling , plate manipulation , plate washing , and spectrophotometric detector . All components must be integrated into a complete system controlled by a single software interface . System must not require the purchase of auxiliary devices to make completely functional . The system must include a laser printer capable of handling the output of the instrument . The complete system must operate on convention 120 volt alternating current typical in laboratories . Manufacturer recommended daily maintenance must be able to be completed by ISP in 10 minutes or less . During initial set - up and check out , the instrument must not demonstrate false negative or positive results related to the design and operation of the instrument . The instrument must be able to operate a full batch of quality control samples and 20 simulated case samples without operator intervention or mechanical failure of any kind . The instrument must have the flexibility to analyze blood , urine , oral fluid and forensic matrices such as vitreous humor fluid without pre - treatment of samples other than simple dilution . The instrument must support on - board dilution of urine samples . Urine samples must not require prior manipulation or treatment by the operator . The system must include all software , hardware , and licenses necessary to perform analysis . Software must include the ability to provide reports in a batched format as well as provide a single page report for individual samples . The system must support the analysis of the following drug or drug classes at the given concentrations in whole blood . Drugs or drug classes at these concentrations must be clearly distinguishable from samples containing no drugs . Amphetamines amphetamine 50 ng / ml Barbiturates secobarbital 100 ng / ml Benzodiazepines oxazepam 50 ng / ml Cocaine metabolite benzoylecgonine 50 ng / ml Opiates morphine 50 ng / ml THC 5 ng / ml Fentanyl 1 ng / ml PCP 10 ng / ml LSD 1 ng / ml Buprenorphine 1 ng / ml Warranty : One - year parts and labor delivered at the laboratory per instrument . 5 - year annual preventive maintenance included . Installation and one time on - site operator training .

Location

Country

United States of America (USA)

State

Illinois

Source

Source

Illinois Purchasing Group

URL

More Details

Record type

Tender

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender