EMERGENCY GENERATOR AND TRANSFER SWITCH PREVENTATIVE MAINTENANCE
Bids closed Mar 2026 · Indiana · Last reported Mar 2026
Source: Indiana Purchasing Group
A . Basic Service scope of work is to be performed as stated below and provided on scheduled visits . B . Lubricating System 1 . First inspection change oil and filters annually ( all new filters will be marked with installation date ) 2 . Approximately 180 days after first inspection , perform complete oil ana
- Status
- Closed
- Sector
- Oil and Gas, Water Supply and Storage, Natural Gas, Biomass
- Location
- Indiana, United States of America
- Updated
- 3 Nov 2026
- Source
- Indiana Purchasing Group
ConstructChat
Ask ConstructChat about EMERGENCY GENERATOR AND TRANSFER SWITCH PREVENTATIVE MAINTENANCE
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | A . Basic Service scope of work is to be performed as stated below and provided on scheduled visits . B . Lubricating System 1 . First inspection change oil and filters annually ( all new filters will be marked with installation date ) 2 . Approximately 180 days after first inspection , perform complete oil analysis and provide written report to Physical Plant Director , within 14 days after inspection . 3 . Lubricate all fittings . 4 . Check and report all leaks . C . Fuel System 1 . Change fuel filters elements annually . 2 . Check generator set for fuel leaks . 3 . Adjust and clean injectors annually . 5 . Check operation of fuel transfer pump and check for leaks . 6 . Check float switch on day tank . 7 . Inspect Main Tank / Day tank fuel levels . 8 . Inspect and test all pressure regulators on propane , natural gas fueled units . 9 . Inspect governor linkage . 10 . Visually Inspect containment basin . 11 . Check for contaminated fuel in above ground and inside day tank ( s ). 12 . Where fuel oil being used , once per year perform a basic fuel analysis with results and interpretations of results provided to the Facilities manager within 14 days of the sample being taken . Basic fuel test to consist of the following items : Sulfur Content , Biodiesel Content , Karl Fischer Water , Particle Count , Elemental Analysis , Microbial Growth , Visual Inspection . |
Location
Country | United States of America (USA) |
State | Indiana |
Source
Source | Indiana Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Oil and Gas, Water Supply and Storage, Natural Gas, Biomass |
Article published date | 2026-04-08 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Oil and Gas tenders in United States of America
- Road Material and Hauling Services
- Used Gasoline Collection Transport Recycling Service
- Town Wide Energy Resilience Master Plan
- ANTIFREEZE OILS AND LUBRICANTS
- Road Material and Hauling Services UPDATED
- Southeast Water Pollution Control Plant Biosolids Digester F...
- Sunol Long Term Improvements Alameda Creek Watershed Center
- City Distribution Division Fueling Station - BID TABULATION