logo

Endoscopy Systems

Sector: Commercial • Location: Silver Spring, Maryland, United States of America

Source: SAM.gov

Tender
Combined Synopsis/Solicitation

Under FDA guidance, this OSEL-DIDSR collaboration requires an endoscope to maximize scientific research capacity throughout the center and agency. An endoscope allows OSEL researchers to develop bench testing methods for evaluating the safety and effectiveness of endoscopy devices. The Government requires an endoscope system (Endoscope) with the following minimum requirements: The Endoscope shall

Status
Prospective
Sector
Commercial, Seaport, Power Generation (CCGT), Residential, Government, Hospital, Water Supply and Storage
Location
Silver Spring, Maryland, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Endoscopy Systems

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Endoscopy Systems” is a tender record in Taiyo, linked to the Commercial sector. It is issued for works, goods, or services related to Silver Spring, Maryland, United States of America.

Participants

Not available for this record.

Status

Original status

combined synopsis/solicitation

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Under FDA guidance, this OSEL-DIDSR collaboration requires an endoscope to maximize scientific research capacity throughout the center and agency. An endoscope allows OSEL researchers to develop bench testing methods for evaluating the safety and effectiveness of endoscopy devices. The Government requires an endoscope system (Endoscope) with the following minimum requirements: The Endoscope shall be shipped to the following address: Attention to: TBD 10903 New Hampshire Ave WO62-3133, US FDA Silver Spring, MD 20993- Shipping cost is included in the total purchase price. The Endoscope shall include the video processor, colonoscope, medical display, and cart that are interoperable with each other. Once assembled, these components shall operate as a fully functional endoscopy system that can acquire and display live image. The video processor shall satisfy the following requirements: The video processor shall be an FDA-cleared 510(k) medical device. The database is publicly available at 510(k) Premarket Notification. The light source shall be integrated within the video processor. The light source shall use three (3) or more LEDs to synthesize different spectra. The video processor shall have the white light mode. The video processor shall have two (2) or more narrow-band imaging (NBI) modes that utilize different optical spectra generated by the LED-based light source. The NBI modes shall be FDA-cleared for visualizing biological features such as blood vessels or mucosal surfaces. The video processor shall have two (2) or more digital color enhancement modes that utilize different digital image processing techniques. These color enhancement modes shall be FDA-cleared under the FDA product code “PEA”. The video processor shall have the following video output ports and video formats: 12G-SDI (3840x2160x60p) 3G-SDI (1920x1080x60p) HD-SDI (1900x1080x60i) The video processor shall have the capability of saving still images in a standard image file format such as TIFF or JPEG. The video processor shall have the capability of saving video clips in a standard video file format. The colonoscope shall satisfy the following requirements: The colonoscope shall be an FDA-cleared 510(k) colonoscope device. The direction of view shall be forward viewing. The field of view shall be 170 ° or wider. The depth of field shall cover the range of 5-100 mm or wider. The angulation (up/down/right/left) shall be 180°/180°/160°/160° or larger. The colonoscope shall have a water nozzle. The insertion tube diameter shall be 12.8 mm or smaller. The colonoscope shall have an instrument channel with diameter of 3.7 mm or larger. The medical display shall satisfy the following requirements: The signal input ports shall include: 12G-SDI 3G-SDI Display Port HDMI DVI The pixel count shall be equal to or greater than 3840x2160 pixels (4K). The display size (diagonal) shall be equal to or greater than 32 inches. All components in the system shall be powered by the standard 120 volts, 60 Hertz alternating current power in the U.S. The Endoscope shall include a total system warranty for at least one (1) year, inclusive of any parts, labor, travel, and shipping cost to return the system to the original equipment manufacturer (OEM) standards.The Contractor shall deliver the endoscope within six (6) weeks of contract award. The Contractor shall provide a one (1)-year warranty period following system acceptance.

Original sector

Wholesale Trade

Location

Country

United States of America (USA)

State

Maryland

City

Silver Spring

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Commercial, Seaport, Power Generation (CCGT), Residential, Government, Hospital, Water Supply and Storage

Article published date

2026-09-15

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender