Etolin Heights Water Heater Removal and Replacement
Sector: Water Supply and Storage • Location: Alaska, United States of America
Source: Alaska Purchasing Group
The Etolin Heights Hot Water Heater Replacement Project at 730 Zimovia Highway in Wrangell , Alaska includes removing and replacing four existing indirect hot water heaters — one of which was installed in 2024 and must be removed , preserved , and delivered to Alaska Air Cargo for shipment to AHFC Anchorage
- Status
- Closed
- Sector
- Water Supply and Storage, Road, Warehouse
- Location
- Alaska, United States of America
- Updated
- 3 Nov 2026
- Source
- Alaska Purchasing Group
ConstructChat
Ask ConstructChat about Etolin Heights Water Heater Removal and Replacement
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The Etolin Heights Hot Water Heater Replacement Project at 730 Zimovia Highway in Wrangell , Alaska includes removing and replacing four existing indirect hot water heaters — one of which was installed in 2024 and must be removed , preserved , and delivered to Alaska Air Cargo for shipment to AHFC Anchorage to support full equipment standardization . The contractor shall furnish and install four new IBC IWT - 119 MAX indirect water heaters , or an approved equivalent , ensuring all installed heaters are dip - tube - free designs with low - mounted cold - water inlets . Work includes installing new low - point drains on domestic and boiler piping , unions on all piping to allow full heater removal , and shut - off valves on the system side of the piping — reusing existing valves where functional — to provide complete isolation of each water heater ; installing new PRVs ( pressure relief valves ) on all four new units ; installing a new pressure tank and adding a shut - off valve between the system piping and the pressure tank if one does not already exist ; providing new pipe insulation on all new piping labeled clearly with domestic / boiler hot / cold and direction of flow per AHFC standards ; replacing or installing seismic earthquake straps ; and installing both a new auto - vent and a shut - off valve between the system piping and the auto - vent to allow isolation and service without draining the system . All existing mixing valves shall be inspected , function - tested , and adjusted as needed to maintain a consistent 120 ° F supply temperature at fixtures . The contractor shall remove and dispose of three older water heaters , and shall transport only the removed 2024 unit and the existing AHFC spare shelf - stock unit to Alaska Air Cargo for shipment to the AHFC Anchorage warehouse . The contractor is responsible for arranging shipment of these two units as freight collect to AHFC Anchorage , where AHFC will receive them upon arrival . |
Location
Country | United States of America (USA) |
State | Alaska |
Source
Source | Alaska Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Road, Warehouse |
Article published date | 2026-03-27 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender