FC0001719 FA4 - DNR - SDWAN - Solomons - 14175 Solomons Island Rd
Bids closed Mar 2026 · Maryland · Last reported Feb 2026
Source: Maryland Purchasing Group
1 . The PO Contractor shall furnish services required in accordance with the requirements described in section 2 . 8 in the RFP . 2 . As described in Section 2 . 13 of the RFP : a . The Master Contractor shall provide a project manager who shall create a transition - in and transition - out plan with schedules
- Status
- Closed
- Location
- Maryland, United States of America
- Updated
- 3 Nov 2026
- Source
- Maryland Purchasing Group
ConstructChat
Ask ConstructChat about FC0001719 FA4 - DNR - SDWAN - Solomons - 14175 Solomons Island Rd
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 1 . The PO Contractor shall furnish services required in accordance with the requirements described in section 2 . 8 in the RFP . 2 . As described in Section 2 . 13 of the RFP : a . The Master Contractor shall provide a project manager who shall create a transition - in and transition - out plan with schedules for each service delivery location . b . The project manager shall be assigned to the project until the transition - in has been completed . c . The transition - in shall take no longer than 60 days after NTP . d . The transition - in shall be complete when all items identified in Section 2 . 13 . 2 of the Master Contract have been accepted by the Contract Manager as being successfully completed . e . The project manager shall : provide inventory reports on demand during the transition period ; attend transition meetings as requested and act as the Master Contractor ’ s liaison to the transition project ; and prepare and submit to the Contract Manager a closeout report due on the last day of the contract . PERFORMANCE AND MAINTENANCE OF CIRCUITS The services provided under this purchase order shall be maintained in such a manner as to ensure they are highly available and PO Contractor response time and service availability are essential elements of this PORFP . PO Contractor shall maintain end - to - end network availability at a 99 . 7 % uptime for each installed circuit . Additionally , the PO Contractor shall provide maintenance support to the locations specified in this PORFP on a 24x7x365 basis . Failure to satisfy Master Contract service provisioning , service availability , and service restoration requirements shall subject the PO Contractor to liquidated damages as provided for in Section 2 . 22 of the RFP . |
Location
Country | United States of America (USA) |
State | Maryland |
Source
Source | Maryland Purchasing Group |
URL |
More Details
Record type | Tender |
Article published date | 2026-05-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
