Fire Alarm Design & Install

Sector: Broadband • Location: California, United States of America

Source: California Purchasing Group

Tender
Closed

A . A new intelligent reporting , microprocessor - controlled fire detection and notification system shall be installed in accordance with the specifications and as indicated on the Drawings . B . Each Signaling Line Circuit ( SLC ) and Notification Appliance Circuit ( NAC ): Limited to only 80 percent of its total cap

Status
Closed
Sector
Broadband, Metal, Telecommunications, Power Generation (CCGT)
Location
California, United States of America
Updated
3 Nov 2026
Source
California Purchasing Group

ConstructChat

Ask ConstructChat about Fire Alarm Design & Install

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Fire Alarm Design & Install” is a tender record in Taiyo, linked to the Broadband sector. It is issued for works, goods, or services related to California, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

A . A new intelligent reporting , microprocessor - controlled fire detection and notification system shall be installed in accordance with the specifications and as indicated on the Drawings . B . Each Signaling Line Circuit ( SLC ) and Notification Appliance Circuit ( NAC ): Limited to only 80 percent of its total capacity during initial installation . C . Control Panel shall be expandable from 1 to 2 SLC loops as necessary to accommodate future expansion using add - on modules . D . Basic Performance : 1 . Signaling Line Circuits ( SLC ) Serving Addressable Devices : Wired Style 6 ( Class A ). 2 . Initiation Device Circuits ( IDC ) Serving Non - addressable Devices Connected to Addressable Monitor Modules : Wired Class B ( NFPA Style B ). 3 . Notification Appliance Circuits ( NAC ) Serving Strobes and Horns : Wired Class B ( NFPA Style Y ). 4 . On Style 6 or 7 ( Class A ) Configurations : Single ground fault or open circuit on Signaling Line Circuit shall not cause system malfunction , loss of operating power , or ability to report alarm . 5 . Alarm Signals Arriving at Control Panel : Not lost following primary power failure until alarm signal is processed and recorded . 6 . Network Node Communications : a . System shall have the capability of networking with other Control Panels on a single pair of copper wires or fiber optic cables . 7 . Signaling Line Circuits ( SLC ): a . SLC modules shall operate in peer - to - peer fashion with all SLC modules in the Control Panel . b . On loss of an SLC module , each remaining panel shall continue to communicate with the remainder of system , including all SLC and control functions 8 . NAC Circuits : Arranged such that there is a minimum of 1 audible device per fire alarm zone . 9 . Notification Appliance Circuits ( NAC ), and Control Equipment : Arranged such that loss of any 1 NAC circuit will not cause loss of any other NAC circuit in the system . 10 . NAC Circuits : a . Electrically supervised for open and short circuit conditions . b . If a short circuit exists on the NAC circuit , it shall not be possible to activate that circuit .

Location

Country

United States of America (USA)

State

California

Source

Source

California Purchasing Group

URL

More Details

Record type

Tender

Sector

Broadband, Metal, Telecommunications, Power Generation (CCGT)

Article published date

2026-03-27

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender