logo

Fire Suppression Monitoring and Pump Inspections

One of 3,973 tenders Taiyo tracks in Montana.

Source: Montana Purchasing Group

Tender
Closed

PROJECT TITLE : CSU Annual Fire Sprinkler , Fire Alarm , Monitoring and Pump InspectionBACKGROUND / PURPOSE : The contractor shall perform annual inspection on all fire sprinkler , fire alarm systems and jockey pumps at the Crow Service Unit . Sites will include Crow / Northern Cheyenne Hospital , Pryor Health Clinic and

Status
Closed
Sector
Hospital
Location
Montana, United States of America
Updated
3 Nov 2026
Source
Montana Purchasing Group

ConstructChat

Ask ConstructChat about Fire Suppression Monitoring and Pump Inspections

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Fire Suppression Monitoring and Pump Inspections” is a tender record in Taiyo, linked to the Hospital sector. It is issued for works, goods, or services related to Montana, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

PROJECT TITLE : CSU Annual Fire Sprinkler , Fire Alarm , Monitoring and Pump InspectionBACKGROUND / PURPOSE : The contractor shall perform annual inspection on all fire sprinkler , fire alarm systems and jockey pumps at the Crow Service Unit . Sites will include Crow / Northern Cheyenne Hospital , Pryor Health Clinic and Lodge Grass Health Clinic . SCOPE : Inspection for the Automatic Fire Protection System at the Crow Hospital , Pryor Health Clinic and Lodge Grass Health Clinic . The survey will include :• One Annual Inspection - Survey and Fire Pump Test to include testing the antifreeze solution and appropriate valves .• Three ( 3 ) Quarterly Inspection — Testing the Supervisory Switches and Alarms at each location .• One complete Annual inspection of the Fire Alarm System as outlined in NFPA - 72 . Testing shall include fire alarm initiating devices , notification devises , fire alarm control panel functions , and any auxiliary functions that may be connected to the FACP Written documentation of the testing . Documentation shall be provided to owner .• Ancillary Devices to be tested : Remote Annunciator , Kitchen Hood ( Ansul Units ), Digital Dialer ( check out ).• Annual Fire Extinguisher Inspections and certification , sixty - seven ( 67 )• Semi - Annual Inspection and Certification of Kitchen Hood Fire Suppression System ( 1 )• Hand on live fire training for 354 individuals .• Fire Sprinkler Inspection and Fire Sprinkler Pump Test for Pryor Clinic , Lodge Grass Clinic and Crow Northern Cheyenne Hospital .• Annual back flow testing for each location ( 3 )• Fire Alarm Monitoring Services for 3 locations

Location

Country

United States of America (USA)

State

Montana

Source

Source

Montana Purchasing Group

URL

More Details

Record type

Tender

Sector

Hospital

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender