Fire Suppression Monitoring And Pump Inspections
Combined synopsis/solicitation · Montana
Source: SAM.gov
PROJECT TITLE: CSU Annual Fire Sprinkler, Fire Alarm, Monitoring and Pump Inspection BACKGROUND/PURPOSE: The contractor shall perform annual inspection on all fire sprinkler, fire alarm systems and jockey pumps at the Crow Service Unit. Sites will include Crow/Northern Cheyenne Hospital, Pryor Health Clinic and Lodge Grass Health Clinic. SCOPE: Inspection for the Automatic Fire Protection System a
- Status
- Closed
- Sector
- Hospital, Residential, Commercial
- Location
- Crow Agency, Montana, United States of America
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Fire Suppression Monitoring And Pump Inspections
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | combined synopsis/solicitation |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | PROJECT TITLE: CSU Annual Fire Sprinkler, Fire Alarm, Monitoring and Pump Inspection BACKGROUND/PURPOSE: The contractor shall perform annual inspection on all fire sprinkler, fire alarm systems and jockey pumps at the Crow Service Unit. Sites will include Crow/Northern Cheyenne Hospital, Pryor Health Clinic and Lodge Grass Health Clinic. SCOPE: Inspection for the Automatic Fire Protection System at the Crow Hospital, Pryor Health Clinic and Lodge Grass Health Clinic. The survey will include: • One Annual Inspection-Survey and Fire Pump Test to include testing the antifreeze solution and appropriate valves. • Three (3) Quarterly Inspection—Testing the Supervisory Switches and Alarms at each location. • One complete Annual inspection of the Fire Alarm System as outlined in NFPA-72. Testing shall include fire alarm initiating devices, notification devises, fire alarm control panel functions, and any auxiliary functions that may be connected to the FACP Written documentation of the testing. Documentation shall be provided to owner. • Ancillary Devices to be tested: Remote Annunciator, Kitchen Hood (Ansul Units), Digital Dialer (check out). • Annual Fire Extinguisher Inspections and certification, sixty-seven (67) • Semi-Annual Inspection and Certification of Kitchen Hood Fire Suppression System (1) • Hand on live fire training for 354 individuals. • Fire Sprinkler Inspection and Fire Sprinkler Pump Test for Pryor Clinic, Lodge Grass Clinic and Crow Northern Cheyenne Hospital. • Annual back flow testing for each location (3) • Fire Alarm Monitoring Services for 3 locations |
Original sector | Public Administration |
Location
Country | United States of America (USA) |
State | Montana |
City | Crow Agency |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Hospital, Residential, Commercial |
Article published date | 2026-01-17 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Hospital tenders in United States of America
- Police and Fire Joint Operations Facility
- FURNISHING AND DELIVERY OF TOXICOLOGY SERVICES
- Certified Recovery Peer Specialists and Substance Use Case Managers Pinellas Medication Assisted Treatment and Emergency Referrals to Services Matters
- RFP 845402021DH Medical Administrator and Pharmacy Benefit Manager
- Emergency Medical TransportAdvanced Life SupportAmbulance Services
- Emergency Medical Services EMS Feasibility Study
- RFP 1003902023KA Temporary Medical Staffing Services
- Medical Examiner Morgue Body Cooler Racks