logo

Fuel Storage Tank System Testing and Certification Services

Sector: Road • Location: California, United States of America

Source: California Purchasing Group

Tender
Closed

A . For facilities with AST ' s , annual testing requirements must be met . Contractor shall perform testing within the testing schedule of local agencies . B . For facilities with UST ' s , testing is required both annually and some components are required to be tested every three years . Contractor shall perform

Status
Closed
Sector
Road
Location
California, United States of America
Updated
3 Nov 2026
Source
California Purchasing Group

ConstructChat

Ask ConstructChat about Fuel Storage Tank System Testing and Certification Services

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Fuel Storage Tank System Testing and Certification Services” is a tender record in Taiyo, linked to the Road sector. It is issued for works, goods, or services related to California, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

A . For facilities with AST ' s , annual testing requirements must be met . Contractor shall perform testing within the testing schedule of local agencies . B . For facilities with UST ' s , testing is required both annually and some components are required to be tested every three years . Contractor shall perform testing within the testing schedule of local agencies . C . Sites that have Healy Model 9961 Clean Air Separator and VST ( Vapor System Technologies ) Phase II EVR ( Enhanced Vapor Recovery ) System with Veeder Root canister must perform testing in accordance with most current edition of CARB EO ( Executive Order ) 201 and EO 203 . D . Testing of PN ( PressureNacuum ) caps within South Coast Air Quality Management District will be tested every three ( 3 ) years on both AST and UST . E . If required by local regulatory agencies , Overfill Prevention Equipment ( OPE ) Inspection will be performed every three ( 3 ) years . If performed on an unleaded fuel tank , vapor reverification is required for UST . F . Vapor recovery testing , TP - 201 . 1CID Drop Test and TP - 201 . 3 Pressure Decay Test ( ST - 30 ) will be performed annually on UST .

Location

Country

United States of America (USA)

State

California

Source

Source

California Purchasing Group

URL

More Details

Record type

Tender

Sector

Road

Article published date

2026-03-27

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender