Generator Maintenance Arnegard ND

One of 3,198 tenders Taiyo tracks in North Dakota.

Source: North Dakota Purchasing Group

Tender
Closed

Equipment : A list of all generators to be covered under this contract can be found in Attachment A . Description of Services : The City of Arnegard will provide a modem to allow for monitoring of communications from the generator . The Contractor shall receive all notifications from the generator and be

Status
Closed
Sector
Water Supply and Storage, Oil and Gas, Energy Storage
Location
North Dakota, United States of America
Updated
3 Nov 2026
Source
North Dakota Purchasing Group

ConstructChat

Ask ConstructChat about Generator Maintenance Arnegard ND

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Generator Maintenance Arnegard ND” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to North Dakota, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Equipment : A list of all generators to be covered under this contract can be found in Attachment A . Description of Services : The City of Arnegard will provide a modem to allow for monitoring of communications from the generator . The Contractor shall receive all notifications from the generator and be the 1st call when an issue arises . The City ’ s designated representative will be the 2nd call . For the duration of this agreement , a successful bidder , during normal business hours , shall inspect the equipment , one of which will include two ( 2 ) visits per year with the descriptions of services provided below : ( This list may not be all inclusive , the expected outcome is that all equipment will be maintained to allow reliable , efficient operation at any time ) A . Engine - Fuel System • Main fuel supply level • Solenoid valve operation • Water in the system • Flexible hose connectors • Tank vents • Unobstructed overflow piping • All piping conditions • Leaks • Fuel Samples B . Lubrication System • Oil level • Oil Heater if applicable • Crankcase Breather • Leaks C . Cooling System • Fluid Level ( topping off to be included up to 1 gallon per year ) • Antifreeze condition and protection level • Radiator air flow • Radiator exterior free from debris • Drive belts • Water pumps • Flex hoses and connections • Engine Coolant heater • Duct work and louvers • Louver motor controls if applicable • Leaks D . Exhaust System • Leakage • Drain condensate trap • Insulation and fire hazards • Exhaust hangars and supports E . Battery / Charging System • Electrolyte levels • Clean and tightening terminals • Remove Corrosion • Install anti corrosion rings • Battery charger and charge rate • Test CCA Rating F . Electrical System • Tighten control wires • Check Wire chafing • Safety and alarms • Boxes , panels , and cabinets • Circuit Breakers and fuses G . Ignition system • Ignition system - plugs , plug wires , points , coil , cap , rotor H . Generator • Brush length , appearance • Commutator slip rings • Main rotor and stator • Bearings • Exciter rotor and stator ( PMG ) • Voltage regulator • Unusual conditions , noises , • vibrations , temperatures , • and deteriorations • Enclosure or service room kept clean ( Note that not all items are applicable to all equipment ) In addition to the services listed , one ( 1 ) visit per year will include services described as : A . Oil and Filter Change Remove the existing engine oil and recharge the engine with new manufacturer approved oil . Remove and replace oil filters , fuel filters , and water filters ( if applicable ) Record contaminated oil condition . Dispose of contaminated oil in the appropriate , safe , and legal manner . B . Automatic Transfer Switch Inspection : inspection the following : Main contactor pads Control relays and circuit boards Control loose connections Settings of time delays Operation of the exercise clock , recording results Check and record voltage sensing relays / devices C . Load Bank Testing Conduct a 2 - Hour duration test , which includes : Visual Inspection Start and run generator Connection resistive load bank to generator for testing Record Data of KW , Percent Load applied , voltage , amps , Hz , temperature , oil pressure , run time and time stamp .

Location

Country

United States of America (USA)

State

North Dakota

Source

Source

North Dakota Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Oil and Gas, Energy Storage

Article published date

2026-04-08

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender