logo

High-Performance Liquid Chromatography System

Sector: Steel • Location: Madison, Wisconsin, United States of America

Source: SAM.gov

Tender
Sources Sought

Description of Specifications - HPLC system with ECD, including computer, software, and installation: Minimum requirements for the HPLC system we require: The system should have all essential parts of an HPLC, to include: Autosampler, a degasser module, pumps, a column oven and columns, a detector, a controller, and all of the necessary tubing and accessories required to run the system, including

Status
Closed
Sector
Steel, Metal, Manufacturing (Industrial), Raw Materials, Commercial, Residential
Location
Madison, Wisconsin, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about High-Performance Liquid Chromatography System

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “High-Performance Liquid Chromatography System” is a tender record in Taiyo, linked to the Steel sector. It is issued for works, goods, or services related to Madison, Wisconsin, United States of America.

Participants

Not available for this record.

Status

Original status

sources sought

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Description of Specifications - HPLC system with ECD, including computer, software, and installation: Minimum requirements for the HPLC system we require: The system should have all essential parts of an HPLC, to include: Autosampler, a degasser module, pumps, a column oven and columns, a detector, a controller, and all of the necessary tubing and accessories required to run the system, including the software necessary to connect to the controller and run the system. All major parts of the system (I.E. the pumps, detector, column oven, controller, etc.) should be from the same manufacturer or at least supported (as in troubleshooting support) by the same manufacturer. The parts of the system which lie within the flow path which carries the various buffers and samples through the system must not contain metal. No part of the flow path should contain stainless steel and all tubing used should consist of PEEK tubing, a hardy, non-reactive plastic tubing commonly used for various HPLC setups where metal is not possible due to the nature of the assayed samples and/or buffers necessary during analysis. PEEK tubing is required . The system and flow path must also be capable of enduring a wide range of pH, from 1.0-14.0, as many buffers used in our assays are at the extreme ends of the pH scale. Minimum pressure tolerance of at least 20 MPa (2900 psi) The system must have multiple pumps (at least 2), or at absolute minimum a single pump capable of generating gradients from multiple inputs. Specific non-detector potions of the system: The solvent delivery system should be able to operate in constant flow or constant pressure modes. The pumps must have a high flow rate accuracy (+ or - 2%) and precision (0.06%) The pumps should come equipped with a suction filter to prevent particulate contamination. As this will be in the flow path, it should be non-metal, ideally ceramic. The autosampler must provide temperature control to the sample compartment (between 4-40C minimum) The autosampler must have a high injection volume accuracy (+ or – 1%) and low injection volume variance (<0.3%) The HPLC will require a specific type of detector called an electrochemical detector (ECD). The detector should either be manufactured by the same manufacturer as the other major parts, or at least be supported (as in Troubleshooting support) by the same manufacturer as the other major parts. The detector should also come with an Au (gold) electrode, as this is the electrode type needed for sugars analysis. The system is perferred to be modular and allow the installation of additional detectors in future. Any HPLC option considered should include technical installation and initial testing of the system;. The technician performing the installation is required to be a U.S. Citizen. Additional System Specifications: System Controller Supports remote monitoring Mobile phases can be purged and baselines checked easily via touch panel. Solvent Delivery Pump Auto-diagnostics to detect problems during analysis, and an auto-recovery function Duel solvent delivery system to reduce space Degassing Unit Can handle up to 3 degassed solvents Autosampler/Plate Changer Fast injection speed Continuous analysis of hundreds of samples High-reproducibility and ultra-low carryover for micro-volume injections Automated sample preparation functions Column Oven Automatic management of column information such as number of injections and pressure during analysis Monitoring of column degradation through usage history Electrochemical Detector Ability to detect carbohydrates using high-performance anion exchange chromatography with pulsed amperometric detection. There should be a warrantee of at least 1 year, and preferably 2 years or more, for the system.

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Wisconsin

City

Madison

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Steel, Metal, Manufacturing (Industrial), Raw Materials, Commercial, Residential

Article published date

2026-03-04

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender