logo

Home Repair

Bids closed Apr 2026 · North Carolina · Last reported Apr 2026

Source: North Carolina Purchasing Group

Tender
Closed

9007 CLEAN TO CLEARANCE 1 . 00 SF_______________ Prior to final acceptance of the lead hazard reduction work and all rehabilitation work , the property shall be visually inspected for any remaining paint chips , dust and debris and lead dust wipe samples shall be obtained from floors , windows sills and wind

Status
Closed
Sector
Natural Gas, Metal, Chemical (Industrial), Steel, Water Supply and Storage, Rail, Manufacturing (Industrial), Commercial, Cement, Residential, Road
Location
North Carolina, United States of America
Updated
3 Nov 2026
Source
North Carolina Purchasing Group

ConstructChat

Ask ConstructChat about Home Repair

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Home Repair” is a tender record in Taiyo, linked to the Natural Gas sector. It is issued for works, goods, or services related to North Carolina, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

9007 CLEAN TO CLEARANCE 1 . 00 SF_______________ Prior to final acceptance of the lead hazard reduction work and all rehabilitation work , the property shall be visually inspected for any remaining paint chips , dust and debris and lead dust wipe samples shall be obtained from floors , windows sills and window troughs . The contractor meet the current HUD clearance level requirements for lead dust . The contractor shall re - clean all applicable components and surfaces and pay for all additional clearance dust sampling if any dust sample result exceed the current HUD clearance levels for lead dust . 9129 CLEAN TO CLEARANCE 1 . 00 SF _______________ After completion of all lead hazard reduction activities , wet mist , fold and remove all containment polyethylene sheeting . HEPA vacuum all visible surfaces including walls , floors , ceilings and window troughs from the top down . Detergent scrub all horizontal surfaces in small sections using a 3 - bucket system , changing rinse water every 250 SF . Completely rinse with clean water and new equipment . After surfaces are dry , HEPA vacuum all visible surfaces except ceiling . 9438 WINDOW - MISC REPAIR 12 . 00 EA _______________ Rewrap all the windows around the house . Window casing & Sills per lead - based paint report . 9494 DOOR - STABILIZE & MISC PAINT 1 . 00 EA________________ STABILIZE AND PAINT . SIDE D - LEFT . DOOR CASING , DOOR JAMB , AND THRESHOLD . 9532 EXTERIOR DOOR -- REPLACE WITH METAL PREHUNG 1 . 00 EA________________ After establishing any required floor containment with polyethylene sheeting , wet mist , remove , wrap in polyethylene sheeting and dispose of door , frame and casing . Install a prehung , insulated , 4 panel , metal skinned door including magnetic weather stripping , interlocking threshold , wide angle peep site , dead bolt and entrance locksets . Retrim opening with 1 " x 6 " casing and brick molding . Prime and prep all wood with premium acrylic latex . SHED DOOR UNDER CARPORT . 9642 ENCLOSE SHEATHING / VINYL 1 . 00 SF________________ Apply 1 / 4 " composition board vapor barrier to enclose to lead containing paint . Protect board with vinyl siding and aluminum or vinyl wrapped trim installed in accordance with manufacturer ' s specifications . Owner ' s choice of pattern , color and embossing . THE ORIGINAL VINYL SIDING WILL BE RE INSTALLED . CLEAN TO CLEARANCE . Environmental Rehab 9657 ENCLOSE TRIM -- ALUMINUM 1 . 00 LF ________________ After establishing any required ground containment with polyethylene sheeting , mark " Lead Paint " every 10 linear feet . Enclose trim with . 024 white aluminum formed on a machine brake with tight lap joints , folded hem edges and accurately fitted connections . Back caulk all seams with 25 year siliconized acrylic and flash head joints to create an weathertight seal . HEPA vacuum all paint chips , dust and debris . FRONT PORCH HEADER & FACIA AROUND THE HOUSE . 9658 ENCLOSE SOFFIT -- ALUMINUM 1 . 00 LF ________________ After establishing any required ground containment with polyethylene sheeting , mark " Lead Paint " every 10 linear feet . Enclose trim with . 027 aluminium non - vented soffit panels , color selected by owner . Back caulk all seams with siliconized acrylic to create a weathertight seal . HEPA vacuum all visible paint chips , dust and debris . 9693 ENCLOSE PORCH CEILING -- PLYWOOD 1 . 00 SF________________ After establishing any required ground containment with polyethylene sheeting , mist defective paint with water to the point of saturation . Wet scrape and HEPA vacuum any visible paint chips , dust and debris . Mark ceiling " Lead Paint " 4 ' on center . Apply a 3 / 8 " BCX plywood ceiling with 7d screw shank nails , 8 " on center and B side exposed . Trim perimeter with 1 / 4 round and seams with 2 " lattice . Prime and top coat with premium acrylic latex . REMOVE THE VINYL , ENCAPSULATE AND REINSTALL VINYL . CLEAN TO CLEARANCE . Carpentry 2974 WINDOW REPLACE -- VINYL -- SGL HNG ENERGY STAR - 1 . 00 EA ________________ W / TRIM > 100 UI Replace existing window that is > ( greater than ) 100 UI ( United Inches ). After establishing any required floor containment with polyethylene sheeting , wet mist , remove , wrap in polyethylene sheeting and dispose of any components containing Lead Based Paint . Detergent wash , rinse , allow to dry and HEPA vacuum any paint chips , dust and debris . Field measure and install a PVC , 1 over 1 , single hung , double glazed , Low E window that meets the ENERGY STAR standards for this climate for U value and SHGC , and is AAMA certified per AAMA / WDMA / CSA 101 / I . S . 2 / A440 - 11 . Include 1 / 2 screen . Wrap exterior jamb and sill with . 027 " aluminum coil stock back caulked and nailed 6 " on center . Re - trim opening with casing , apron and stool to match existing . Prep for paint . LAST WINDOW ON THE RIGHT SIDE OF HOME . 3160 DOOR -- INSULATED METAL Front & Back Door 2 . 00 EA ________________ Install a 6 - panel , insulated metal door on the existing jamb , with entrance lockset and mortised dead bolt keyed alike . Include three 4 " x 4 " hinges , interlocking threshold , neoprene weatherstripping , and wide angle peepsight . Prime and topcoat . 3520 PORCH HAND RAIL -- 2 " X 4 " Front & Back Steps 2 . 00 LF ________________ Install preservative treated 2 " x 4 " handrail supported by 4 " x 4 " treated posts , 4 ' on center . Rail to be free from cracks , splinters , and rough edges . Set first post in a 12 " x 8 " x 12 " concrete sleeve , bolt remaining posts to stringer with 7 " lags . Roofing 4546 EPDM -- FULLY ADHEARED 1 . 00 SQ ________________ Clean all loose materials off of roof . Install manufacturers approved underlayment board . Install a 60 mil EPDM single ply membrane with adhesive per manufacturer ' s specs . All membrane flashing , metal flashings and counter flash cones , as well as installation procedure to follow manufacturer ' s specs . Furnish Owner w / 20 year labor and materials warranty . 4580 TEAR OFF AND REROOF SHINGLES 1 . 00 SQ ________________ Remove and dispose of all roofing & defective sheathing . Cut a 1 " wide vent at ridge board . Replace up to 200 sf of sheathing roof using pine board or CDX plywood of matching thickness . Staple 15 lb felt . Install preformed white aluminum , drip edge , and vent pipe boots . Install a 220 lb fiberglass asphalt , 3 tab shingle with a 25 yr warranty . Replace all flashing . Install shingle - over ridge vent . HVAC 6059 PACKAGE - UNIT -- REPLACE -- AC WITH NATURAL GAS 1 . 00 EA ________________ HEAT -- WITH DUCTWORK Use the Air Conditioning Contractors of America ' s ( ACCA ) late test edition of their Manual J calculation tool http :// www . acca . org / tech / manualj / ( calculate manual J based on the post rehab building envelope ), use ACCA ' s Manual S for equipment selection and use Manual D for ductwork design . Make every effort to install supply ducts in interior partitions ( in conditioned wall cavities ). NOTE : Provide Manual J , S and D reports before work begins . Size furnace to the living unit considering any areas which may be added or subtracted from the plan . Remove existing package unit , recycle all metal components and dispose of all other materials in a code legal dump . Install a package unit with a heat pump rated at a minimum of 15 SEER for cooling and a natural gas fired backup burner with a minimum AFUE rating of 81 % or higher ,

Location

Country

United States of America (USA)

State

North Carolina

Source

Source

North Carolina Purchasing Group

URL

More Details

Record type

Tender

Sector

Natural Gas, Metal, Chemical (Industrial), Steel, Water Supply and Storage, Rail, Manufacturing (Industrial), Commercial, Cement, Residential, Road

Article published date

2026-05-05

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender