Hvac
The scope, dates and status of this tender. A free account opens every field.
Source: SAM.gov
Manufacturing, delivery and assembly of entire air conditioning system, consisting of: 1. Job Site Mobilization - Construction site setup - Work platform, scaffolding, and/or ladders. Installation height: max. 3.50 m above floor. 2. Air conditioning system, consisting of: Description: REMKO MVV 2003 DC Quantity: 1 each Manufacturer: Remko Model: MVV 2003 DC Item number: 1623680 Description: Floor
- Status
- Closed
- Sector
- Hydrogen, Chemical (Industrial), Fertilizers, Cement, Geothermal, Aerospace & Defense, Power Generation (CCGT), Metal, Manufacturing (Industrial), Oil and Gas, Government, Commercial, Residential
- Location
- Kaiserslautern, DE-RP, Germany
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Hvac
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | presolicitation |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Manufacturing, delivery and assembly of entire air conditioning system, consisting of: 1. Job Site Mobilization - Construction site setup - Work platform, scaffolding, and/or ladders. Installation height: max. 3.50 m above floor. 2. Air conditioning system, consisting of: Description: REMKO MVV 2003 DC Quantity: 1 each Manufacturer: Remko Model: MVV 2003 DC Item number: 1623680 Description: Floor console BK-1000 Plus S Quantity: 1 each Manufacturer: Remko Model: BK-1000 Plus S Item number: 1613273 Description: Condensate collection tray incl. oil separator MVV 2000/Duo Quantity: 1 each Manufacturer: Remko Model: MVV 2000/Duo Item number: 260128 Description: REMKO MVW 222 Quantity: 9 each Manufacturer: Remko Model: MVW 222 Item number: 1623504 Description: KFB-4 wired remote control Quantity: 9 each Manufacturer: Remko Model: MVD 222-1002/MVW 222-562 Item number: 1613269 - Fixed price for the refrigeration connection of indoor air conditioning units in connection with the technical handover of equipment by REMKO (also for A2L refrigerants in accordance with DIN EN 60335-2). - The contractor must announce all necessary power requirements for CTS pre-installation. 3. Pipe network: Refrigerant pipes made of seamless drawn copper from Cu-DHP, strength R220 soft according to EN 12735-1, cleaned inside, pipe ends sealed, with factory-fitted thermal insulation made of modified polyethylene according to DIN EN 14313 with structured white protective film. Building material class flame retardant CL s1 d0 according to DIN EN 13501-1, does not drip when burning, minimal smoke development. Permissible operating pressure 169 bar with 3-fold safety up to 100 °C according to EN 14276. Installation of pipes in accordance with DIN EN 378-2 and DKI i.164, copper pipes in refrigeration and air conditioning technology. Brazing using silver or phosphorus solders in a protective gas atmosphere. Pressing with special press fittings for refrigerant-carrying pipes in accordance with DIN EN ISO 14903. Brazing is carried out using brazing alloys in accordance with DIN EN ISO 17672, recommended brazing alloys CuP 179 or CuP 279, if necessary, fluxes in accordance with DIN EN 1045 type FH10 must be used. For solders AG 134, AG 145, and AG 244, use flux in accordance with DIN EN 1045. Type: FH 10. Brazed joints may only be made by qualified personnel. Before and during the joining process by brazing or welding, the pipes must be flushed with dry protective gases, e.g., inert gases (noble gases, nitrogen, and mixtures thereof) or forming gases (e.g., nitrogen-hydrogen, nitrogen-argon, etc., max. hydrogen content 4 vol.%). When using capillary solder and press fittings, consult the respective fitting manufacturer regarding the possible areas of application, particularly the maximum permissible operating pressures. Pipe network consisting of following components: Description: Refrigeration pipe, insulated, installed according to design. Quantity: according to design Manufacturer: Remko Model: 3/8”, 3/4”, 1/4”, 1/2”, Item number: 260128 Description: Y-distributor set for MVV AT/IT fluid and suction line Quantity: 2 sets Manufacturer: Remko Item number: 1611095 Description: 4-way distributor set for liquid gas and suction line Quantity: 2 sets Manufacturer: Remko Item number: 1611096 Description: Condensation hose 16/18 mm diameter, per meter Quantity: 1 each per wall unit Manufacturer: Remko Item number: 1613053 Description: Condensation pump KP-6 Quantity: 1 each per wall unit Manufacturer: Remko Item number: 1613251 The installation of the distribution sets involves connecting and soldering the refrigerant lines already connected by the installer to the distributors. Since absolute cleanliness must be ensured in this complex pipe system, soldering is carried out under dry nitrogen. 4. Miscellaneous / Additional services, special services: - The pipe dimensions must be checked by the contractor and adjusted if necessary. - The contractor must adjust the system components so that the planned functions and performance are achieved and the legal requirements are met. The air volume flows must be adjusted in accordance with the calculated settings. Measured values must be documented. - The contractor shall provide one-time training for the operating and maintenance personnel for the system. Leading time for coordination: 2 weeks. - If necessary, the delivery and installation of special fastening structures, e.g., brackets and support frames is also part of this contract. - Delivery of the operating materials and media required for commissioning and trial operation, particularly the required refrigerant R 410A. 5. As-built documentation As-built documentation, digital revision documents in German and English language including: - System diagrams. - General electrical diagrams and connection diagrams in accordance with DIN EN 61082-1 “Electrotechnical documentation ” - Compilation of the key technical data. - Copies of the required test and manufacturer certificates. - All operating and maintenance documents, required for safe and economical operation. - Protocol on the training of maintenance and operating personnel. FAR 52.225-5, Trade Agreements“One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements. |
Original sector | Wholesale Trade |
Location
Country | Germany |
State | DE-RP |
City | Kaiserslautern |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Hydrogen, Chemical (Industrial), Fertilizers, Cement, Geothermal, Aerospace & Defense, Power Generation (CCGT), Metal, Manufacturing (Industrial), Oil and Gas, Government, Commercial, Residential |
Article published date | 2026-03-31 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Hydrogen tenders in Germany
- H2G Wasserstoffsystem
- Wissenschaftliche Unterstützung zur Weiterentwicklung von Instrumenten zum Markthochlauf Wasserstoff und seiner Folgeprodukte
- Bau von Hochbaumaßnahmen, Außenanlagen und Verkehrsflächen im Zusammenhang mit der Herstellung von Wasserstoff
- H2G Planung Reallabor Wasserstoff
- H2G Planung Reallabor Wasserstoff
- RV für die zerstörungsfreie Schweißnahtprüfung v. Baustellennähten für Gas, Wasserstoff u. Fernwärme
- Lieferung eines Wasserstoffspeichers und eines Wasserstoffblockheizkraftwerks
- Gaschromatograph
