Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES )

One of 1,967 tenders Taiyo tracks in Vermont.

Source: Vermont Purchasing Group

Tender
Closed

Through this Request for Proposal ( RFP ) the Office of Purchasing & Contracting ( hereinafter the “ State ”) is seeking to establish contracts with one or more companies that can provide Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES ), chiller , autosampler , computer and software for the Metals Labo

Status
Closed
Sector
Water Supply and Storage, Residential, Fertilizers, Raw Materials, Commercial
Location
Vermont, United States of America
Updated
3 Nov 2026
Source
Vermont Purchasing Group

ConstructChat

Ask ConstructChat about Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES )

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES )” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to Vermont, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Through this Request for Proposal ( RFP ) the Office of Purchasing & Contracting ( hereinafter the “ State ”) is seeking to establish contracts with one or more companies that can provide Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES ), chiller , autosampler , computer and software for the Metals Laboratory . DETAILED REQUIREMENTS : ICP - OES Instrument Specifications The Vermont Agriculture Environmental Laboratory ( VAEL ) requests proposals for an Inductively Coupled Plasma Optical Emission Spectrometer ( ICP - OES ), chiller , autosampler , computer and software for the Metals Laboratory . This system must be capable of performing feed & fertilizer analyses and EPA method 200 . 7 . The instrument must allow for calibration and detection of multiple analytes in a single sequence . 2 . 1 System Requirements : 2 . 1 . 1 Must include a new , bench - top fully automated system , with a footprint less than 35 ” x 30 ” x 25 ” ( H X D X W ). 2 . 1 . 2 Must have a simultaneous , solid - state detector with the ability to detect > 95 % of the wavelengths in the 167nm - 785nm range . 2 . 1 . 3 The detector should be chilled to at least - 35ºC to minimize dark current signal , enhancing instrument performance and detection limits . 2 . 1 . 4 The detector must be hermetically sealed and require no gas consumption for detector purging . 2 . 1 . 5 Must have dual viewing modes with the option to read axially and radially in a 2 - step sequential process or read axial and radial views alone . 2 . 1 . 6 The ICP - OES must use Argon ( 99 . 99 % purity ) only for operation . Total system gas flow for operation should not exceed 25 L / min . 2 . 1 . 7 All gas flows controlling the plasma should have Mass Flow Controllers . This includes plasma gas ( coolant ), auxiliary gas , nebulizer gas and make up gas . 2 . 1 . 8 Must have a water chiller . 2 . 1 . 9 Autosampler must be capable of holding at least 180 - 15mL autosampler tubes with a well for automatic sampler probe rinsing between samples . 2 . 1 . 10 The system must include a computer with Windows 11 operating system and manufacturer software capable of running all system components . 2 . 1 . 11 The instrument must have a standard single piece design vertical plasma torch 2 . 1 . 12 The instrument must have a five ( 5 ) channel , variable speed , and computer - controlled peristaltic pump to allow for on - line addition of internal standards . 2 . 1 . 13 Customizable , fully serviceable sample introduction setup including but not limited to torch assembly , spray chamber , nebulizer . 2 . 2 Instrument Software Must be capable of the following : 2 . 2 . 1 Automated background correction , removing the user ’ s need to decide upon suitable background points for background correction . 2 . 2 . 2 Automated spectral interference correction . For Traditional Interfering Element Corrections ( IEC ), the software must be able to automatically calculate these values . 2 . 2 . 3 Displaying a continuous full spectrum scan . 2 . 2 . 4 Flag out - of - control data 2 . 2 . 5 Track maintenance components . 2 . 2 . 6 Shut down system automatically after a sequence has ended . 2 . 2 . 7 Meets or exceeds method analysis requirements for SW - 846 and EPA Method 6010D & EPA 200 . 7 . 2 . 2 . 8 Export data and instrument files to a Laboratory Information Management System ( LIMS ).

Location

Country

United States of America (USA)

State

Vermont

Source

Source

Vermont Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Residential, Fertilizers, Raw Materials, Commercial

Article published date

2026-04-28